Related Experiment Video
Updated: Dec 27, 2025

Rodent Estrous Cycle Monitoring Utilizing Vaginal Lavage: No Such Thing As a Normal Cycle
Published on: August 30, 2021
Alterations in vaginal temperature during the estrous cycle in dairy cows detected by a new intravaginal device-a
Shuilian Wang1,2, Hongliang Zhang1,2, Hongzhi Tian1
1Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing, 100193, China.
Abstract:
Estrus identification is important in dairy cow production. At present, estrus identification is automated with a pedometer or accelerometer and the results remain unsatisfactory. It was previously reported that body temperature changes during estrus. In the present study, dairy cow vaginal temperature (VT) was monitored during various seasons, and an increase in VT of 0.3 °C was suggested for the onset of estrus, using an automated VT monitoring system developed in-house. Natural and synchronized estrus were measured simultaneously. The VT was determined to be in circadian rhythm and significantly higher in summer than in either autumn or winter (P < 0.05). VT difference (between estrus VT and average VT 7 days earlier) gradually increased, reached a peak of 0.56 °C ± 0.17 at 4 h before the end of estrus, and then decreased to the normal. The VT of cows in estrus and the duration of their estrus were significantly affected by seasons and estrus types (P < 0.05). VT gradually decreased in response to prostaglandin (PG) injection and was significantly lower (0.15-0.35 °C) from 9 to 33 h after the drug administration than the average VT at the same time 7 days earlier (P < 0.05). Changes in circadian and seasonal VT and in the estrous cycle can be monitored to assess the physiological status of cows and will help in developing an effective automated estrus identification technique. Results of this pilot study should be validated in further studies.
More Related Videos
09:01Performing Vaginal Lavage, Crystal Violet Staining, and Vaginal Cytological Evaluation for Mouse Estrous Cycle Staging Identification
Published on: September 15, 2012
08:16Infrared Thermography for the Detection of Changes in Brown Adipose Tissue Activity
Published on: September 28, 2022
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...