Comparison of neutron and secondary gamma dose assessment using polygon mesh and voxel computational phantoms
Abstract:
The newly developed mesh-type reference computational phantoms (MRCPs) represent the evolution of the previous reference phantoms and a more detailed description of the human body, addressing the voxel reference phantom limitations. These allow for a more accurate dose calculation in the human body, which in some cases results in a significant difference of the calculated quantities. In this work, the absorbed dose calculation due to neutrons and gammas was calculated using a voxel and a mesh-type computational phantom. The goal was to understand how a more accurate description of the human body affects the estimated neutron dose. The phantoms were tested in a real-case scenario: they were placed in front of a neutron Howitzer container model using PHITS. This model corresponds to the neutron Howitzer container at the Neutron Measurements Laboratory of the Energy Engineering Department of the Polytechnic University of Madrid (UPM), and at the time of measurement it was equipped with a 241Am-Be neutron source of 74 GBq in its center. The container allows the source to be in either the irradiation or the storage position. Results show that when dealing with neutrons, the dose deviation when using GOLEM or the MRCP leads to a general 20%-30% deviation that goes up to above 400% in small thin structures such as the eye.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
08:41Patient-Specific Polyvinyl Alcohol Phantom Fabrication with Ultrasound and X-Ray Contrast for Brain Tumor Surgery Planning
Published on: July 14, 2020
Related Concept Videos
Biological Effects of Radiation
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...