Related Experiment Video
Updated: Dec 26, 2025

Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome ARDS
Published on: April 7, 2021
Optimal mean airway pressure during high-frequency oscillatory ventilation in an experimental model of acute
Songqiao Liu1, Zhanqi Zhao2,3, Li Tan1,4
1Department of Critical Care Medicine, Zhongda Hospital, School of Medicine, Southeast University, Jiangsu Province, Nanjing, 210009, China.
Background:
High-frequency oscillatory ventilation (HFOV) may theoretically provide lung protective ventilation. The negative clinical results may be due to inadequate mean airway pressure (mPaw) settings in HFOV. Our objective was to evaluate the air distribution, ventilatory and hemodynamic effects of individual mPaw titration during HFOV in ARDS animal based on oxygenation and electrical impedance tomography (EIT).
Methods:
ARDS was introduced with repeated bronchoalveolar lavage followed by injurious mechanical ventilation in ten healthy male pigs (51.2 ± 1.9 kg). Settings of HFOV were 9 Hz (respiratory frequency), 33% (inspiratory time) and 70 cmH2O (∆pressure). After lung recruitment, the mPaw was reduced in steps of 3 cmH2O every 6 min. Hemodynamics and blood gases were obtained in each step. Regional ventilation distribution was determined with EIT.
Results:
PaO2/FiO2 decreased significantly during the mPaw decremental phase (p < 0.001). Lung overdistended regions decreased, while recruitable regions increased as mPaw decreased. The optimal mPaw with respect to PaO2/FiO2 was 21 (18.0-21.0) cmH2O, that is comparable to EIT-based center of ventilation (EIT-CoV) and EIT-collapse/over, 19.5 (15.0-21.0) and 19.5 (18.0-21.8), respectively (p = 0.07). EIT-CoV decreasing along with mPaw decrease revealed redistribution toward non-dependent regions. The individual mPaw titrated by EIT-based indices improved regional ventilation distribution with respect to overdistension and collapse (p = 0.035).
Conclusion:
Our data suggested personalized optimal mPaw titration by EIT-based indices improves regional ventilation distribution and lung homogeneity during high-frequency oscillatory ventilation.
Related Concept Videos
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: