Related Experiment Video
Updated: Dec 26, 2025

Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Alignment of a wavefront-guided scleral lens correction in the presence of a lens capsulotomy
Lan Chi Nguyen1, Gareth D Hastings1, Matthew J Kauffman1
1Visual Optics Institute, College of Optometry, University of Houston, 4901 Calhoun Rd, Houston, TX 77204 USA.
Purpose:
To demonstrate the necessity of aligning a wavefront-guided scleral lens (WGSL) optical correction to the eye's effective pupil, with misalignments leading to reduced performance.
Case Report:
A 34 year old subject with a history of failed LASIK in the left eye, leading to penetrating keratoplasty, extracapsular extraction of the crystalline lens and neodymium:yttrium-aluminum-garnet (Nd:YAG) laser posterior capsulotomy, enrolled in a study examining WGSL performance. Habitual logMAR acuity OS (aided with a scleral lens) was +0.04. Residual higher order root mean square (HORMS) wavefront error (WFE) was 0.28 μm (Φ =4.75 mm, mean age-matched norm =0.17 μm), and objective over-refraction was -0.30 -0.54 × 008. When a WGSL (targeting aberrations up to the 5 th radial order) was manufactured with the wavefront-guided optics aligned to the center of the dilated pupil, logMAR acuity worsened to +0.15, residual HORMS WFE worsened to 0.44 μm (Φ =4.75 mm), and objective over-refraction increased to +1.19 -0.30 × 122. Slit lamp imagery revealed that the effective pupil was no longer defined by the iris of the eye, but rather the capsular opening created by the capsulotomy. When the WGSL was redesigned to align the wavefront-guided optics to the center of the capsular opening, logMAR acuity improved to -0.14, residual HORMS WFE reduced to 0.17 μm (Φ =4.75 mm) and objective over-refraction reduced to +0.20 -0.15 × 111.
Conclusion:
WGSLs are an emerging option for patients with highly aberrated, ectatic and post-surgical corneas whose visual symptoms cannot be alleviated with conventional corrections. However, alignment of the optics of the WGSL to the underlying optics of the eye over the effective pupil is critical in achieving good optical and visual performance.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
Related Concept Videos
Angle Closure Glaucoma: Treatment
Focusing of Light in the Eye
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview