The accuracy of compressed sensing cardiovascular magnetic resonance imaging in heart failure classifications
Jiajia Wang1, Qing Lin2, Yukun Pan1
1Department of Radiology, Zhengzhou University People's Hospital, Zhengzhou, 450003, Henan, China.
Abstract:
To evaluate the accuracy of compressed sensing (CS) cardiovascular magnetic resonance imaging (CMR) in the classifications of heart failure (HF). One hundred and fifty-four patients underwent 3 T CMR using CS single-breath-hold cine (SBH-cine) after a standard multiple-breath-hold cine (MBH-cine). The image quality of the two methods was compared. Cardiac function parameters were quantitatively analyzed. The patients were divided into different HF types based on diagnostic criteria using two sequences. The scan time for CS SBH-cine was reduced by 88% compared with that of standard MBH-cine. In the non-atrial-fibrillation (NAF) group (n = 121), the image quality score of CS SBH-cine was slightly decreased compared with standard MBH-cine (4.5 ± 0.6 for the CS SBH-cine vs. 4.7 ± 0.5 for the standard MBH-cine, T = 5.038, p < 0.05). In the atrial fibrillation (AF) group (n = 33), the CS SBH-cine image quality score was slightly higher than that of the standard MBH-cine (3.8 ± 0.7 for the CS SBH-cine vs. 3.3 ± 0.5 for the standard MBH-cine, T = - 4.503, p < 0.05). The left ventricular (LV) end diastolic volume, LV end systolic volume, LV ejection fraction, and LV mass index calculated by CS SBH-cine had no significant differences from those calculated by standard MBH-cine. The agreement on HF classifications of both the standard MBH-cine and the CS SBH-cine was excellent (kappa = 0.934, p < 0.05). The result showed that HF could be classified accurately using CS SBH-cine.
Related Concept Videos
Heart Failure IV: Classification and Diagnostic Evaluation
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Pathophysiology of Heart Failure
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...