Related Experiment Video
Updated: Dec 26, 2025

Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
Field Validation of Concrete Transport Property Measurement Methods
Ahmed Abd El Fattah1, Ibrahim Al-Duais2, Kyle Riding3
1Architecture Department, King Fahd University of Petroleum and Minerals, PO. Box 215, Dhahran 31261, Saudi Arabia.
Abstract:
Reinforcing steel corrosion, caused by chloride ingress into concrete, is the leading cause of reinforced concrete deterioration. One of the main findings in the literature for reducing chloride ingress is the improvement of the durability characteristics of concrete by the addition of supplementary cementitious materials (SCMs) and/or chemical agents to concrete mixtures. In this study, standard ASTM tests-such as rapid chloride permeability (RCPT), bulk diffusion and sorptivity tests-were used to measure concrete properties such as porosity, sorptivity, salt diffusion, and permeability. Eight different mixtures, prepared with different SCMs and corrosion inhibitors, were tested. Apparent and effective chloride diffusion coefficients were calculated using bound chloride isotherms and time-dependent decrease in diffusion. Diffusion coefficients decreased with time, especially with the addition of SCMs and corrosion inhibitors. The apparent diffusion coefficient calculated using the error function was slightly lower than the effective diffusion coefficient; however, there was a linear trend between the two. The formation factor was found to correlate with the effective diffusion coefficient. The results of the laboratory tests were compared and benchmarked to their counterparts in the marine exposure site in the Arabian Gulf in order to identify laboratory key tests to predict concrete durability. The overall performance of concrete containing SCMs, especially fly ash, were the best among the other mixtures in the laboratory and the field.
Related Concept Videos
Measurement of Air Content in Concrete
The pressure method,...
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Non-destructive Tests for Concrete Strength
Fineness of Cement
Direct...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Vebe Test
To conduct the test, concrete is placed into the slump cone. The concrete is filled in layers and...