Related Experiment Video
Updated: Dec 26, 2025

A Modified QuEChERS-HPLC Method for Detection of Polycyclic Aromatic Hydrocarbons in Zebrafish Embryos Exposed to Fine Particulate Matter
Published on: June 13, 2025
Layered porous organic frameworks as a novel adsorbent for the solid phase extraction of chlorophenols prior to their
Qianqian Wang1, Gaigai Li1, Chun Wang2
1College of Science, Hebei Agricultural University, Baoding, 071001, China.
Abstract:
A layered porous organic framework (L-POF) with high surface area and porous volume was used as a novel adsorbent for adsorption of chlorophenols (CPs). The L-POF showed much higher adsorption capacity for four CPs (2-CP, 3-CP, 2,3-CP, 2,4-CP) compared with corresponding amorphous POF and some commercial adsorbents. Then, an L-POF-based solid-phase extraction method combined with high-performance liquid chromatography for analyzing CPs at the wavelength of 280 nm in water and honey samples was established. Under the optimum conditions, four CPs exhibited good linearity in the range 0.10-80.0 ng mL-1 for water and 2-400 ng g-1 for honey samples with determination coefficient r2 > 0.996. The method has low limits of detection of 0.03-0.10 ng mL-1 for water and 0.5-1.0 ng g-1 for honey samples. The method presented satisfactory precision and accuracy with relative standard deviations ≤ 7.8% and recoveries of 80-115%. High enrichment factors of 123-190 for water and 63-97 for honey were obtained. The validated method was successfully used to determine CPs in water and honey samples. The L-POF also displayed prominent adsorption performance for many other dyes and organic contaminants. This suggests that it can be an ideal candidate as adsorbent for wide application in separation and analysis. Graphical Abstract.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
10:27Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Related Concept Videos
Extraction: Advanced Methods
Analyte Adsorption and Distribution
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
High-Performance Liquid Chromatography: Elution Process