Related Experiment Video
Updated: Dec 26, 2025

Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
Experimental studies on computed tomographic peritoneography. Peritoneal and residual renal function tolerance to
Jiao Bai1, Jing Dong1, Jian Shu1
1Department of Radiology, Affiliated Hospital of Southwest Medical University, Luzhou, China.
Abstract:
Computed tomographic (CT) peritoneography has been widely used as reference standard to evaluate continuous ambulatory peritoneal dialysis-related complications. However, given the varying CT peritoneography approaches used across different institutions, there is no standard value for non-ionic iodinated contrast media (ICM) concentration. Few studies have currently investigated whether non-ionic iodinated contrast media (non-ionic ICM) affects peritoneal function or residual renal function (RRF). This study aimed to determine whether different non-ionic ICM concentrations affect peritoneum and RRF and attempted to evaluate CT peritoneography images to identify the optimal non-ionic ICM concentrations in animals. To this end, 25 male Sprague-Dawley rats were used to establish uraemic models, after which they were injected with a 40-mL mixture of peritoneal dialysate and iohexol at varying concentrations prior to CT peritoneography. Thereafter, two experienced radiologists blinded to the rat groupings evaluated image quality, peritoneal morphology and thickness were assessed using hematoxylin and eosin and Masson staining, and RRF was evaluated using serum creatinine levels hematoxylin and eosin staining of pathological kidney sections. Briefly, non-ionic ICM had negligible effects on the peritoneum and RRF. Our results suggest that a mixture containing 50 mL (350 mgI/mL) iohexol/2 L peritoneal dialysate can be used as reference in rats.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
09:23Author Spotlight: Enhancing Transplantation Research Through MicroCT Angiography in Murine Models
Published on: September 22, 2023
Related Concept Videos
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies VII: Vascular Imaging
Imaging Studies for Cardiovascular System V: CT
Imaging Studies V: Intravenous Urography and Retrograde Pyelography