Related Experiment Video
Updated: Dec 26, 2025

Expression of Cementitious Pore Solution and the Analysis of Its Chemical Composition and Resistivity Using X-ray Fluorescence
Published on: September 23, 2018
Experimental Examination of Electrical Characteristics for Portland Cement Mortar Frost Damage Evaluation
Yi Wang1,2, Tamon Ueda3, Fuyuan Gong1
1College of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China.
Abstract:
Electrical measurements are promising for evaluation of frost damage of concrete, but the index is still controversial. In this paper, to propose an efficient index, various electrical characteristics were examined to correlate them with the mechanical property degradation of meso-scale mortar samples due to combined effects of sodium chloride and freeze-thaw cycles (FTCs). While the electrical responses of specimens were measured during FTCs, the mechanical properties were obtained from three-point bending tests after FTCs. Typical microstructural change after the damage was also analyzed by using a water absorption test. The results showed that no clear degradation tendency was observed for electrical resistivity at the lowest temperature, the activation energy or the freezing/thawing point change with the FTCs. The reduction in electrical resistivity at reference temperature has a consistent tendency with that of elastic modulus and flexural strength, thus can be an efficient index for quantitative frost damage evaluation. The change due to salt-frost damage is mainly due to the increase of connectivity rather than porosity.
More Related Videos
10:00Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures
Published on: August 31, 2017
11:07Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Related Concept Videos
Frost Resistant Concrete
Introducing microscopic air bubbles into the concrete mix through air entrainment creates small voids that accommodate ice expansion, thereby reducing internal pressures and preventing cracking. The optimal amount of...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Mortar Properties
Frost Action on Concrete
This freeze-thaw cycle primarily causes surface scaling, where...
Mortar Joint Deterioration in Masonry
The...
Mortar