Related Experiment Video
Updated: Dec 26, 2025

15:00
Setup of Consumer Wearable Devices for Exposure and Health Monitoring in Population Studies
Published on: February 3, 2023
2.9K
Wearable Wireless Sensors for Measuring Calorie Consumption
Faranak Fotouhi-Ghazvini1, Saedeh Abbaspour1
1Department of Computer Engineering and IT, Faculty of Engineering, University of Qom, Iran.
Journal of Medical Signals and Sensors
|March 14, 2020
Summary
This study presents a novel wearable system combining accelerometer and photoplethysmography (PPG) sensors for accurate calorie expenditure tracking. The device demonstrates reliable performance, comparable to established health monitoring tools.
Area of Science:
- Biomedical Engineering
- Wearable Technology
- Health Monitoring
Background:
- Wearable tracking devices offer potential for measuring heart rate, energy expenditure, and activity recognition.
- Accurate calorie measurement is crucial for fitness tracking and continuous health monitoring.
Purpose of the Study:
- To develop and validate a wearable system for calculating consumed calories using combined accelerometer and photoplethysmography (PPG) sensors.
- To assess the system's accuracy against gold standards like pulse oximeters and treadmills.
Main Methods:
- Implemented a system combining accelerometer and PPG sensors, transmitting data via Bluetooth to an Android application.
- Utilized sensor fusion, integrating accelerometer data (laws of motion) and PPG data (heart rate) for energy expenditure calculation.
- Applied wavelet denoising to accelerometer signals, reducing variance from 3.2 to 0.8.
Main Results:
- Achieved high correlations: 0.9 between PPG and pulse oximeter, and 0.9 between accelerometer and treadmill.
- Demonstrated low error rates: RMSE of 0.53 (PPG vs. pulse oximeter) and 0.42 (accelerometer vs. treadmill).
- Statistical significance confirmed with P-values of 0.008 and 0.007, respectively.
Conclusions:
- The developed system shows good validity and reliability, comparable to commercial smart bands, watches, and smartphones.
- No significant difference was found when comparing the combined sensor data to gold standards (pulse oximeter, treadmill).
- The wireless, mobile system offers a convenient, anytime, anywhere solution for health and fitness monitoring.
Keywords:
Accelerometeractivity monitoringcalorie consumptionphotoplethysmographysmartphone health applicationMore Related Videos
Related Concept Videos
Equipments Used to Measure Body Temperature
1.6K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
1.6K
Energy Balance
946
The human body gets energy from the three macronutrients: carbohydrates, proteins, and fats. Energy is released when the chemical bonds in the organic compounds present in the food are broken down. The energy content of food is measured in kilocalories (kcal), defined as the amount of heat required to raise the temperature of one kilogram of water by one degree Celsius. This value is determined by measuring the temperature change of the water surrounding a calorimeter after the complete...
946
Guidelines For Measuring Vital Signs
2.6K
Following these guidelines can help nurses accurately measure vital signs, assess changes in patient conditions, and provide timely treatment when necessary. Adhering closely to the guidelines ensures the accuracy and reliability of the results.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
2.6K
Equipments Used To Measure Blood Pressure
2.9K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
2.9K

