Related Experiment Video
Updated: Dec 26, 2025

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
Chaos-Based Analysis of Heart Rate Variability Time Series in Obstructive Sleep Apnea Subjects
Shiva Naghsh1, Mohammad Ataei1, Mohammadreza Yazdchi2
1Department of Electrical Engineering, Faculty of Engineering, University of Isfahan, Isfahan, Iran.
Abstract:
Obstructive sleep apnea (OSA) is a common disorder which can cause periodic fluctuations in heart rate. To diagnose sleep apnea, some studies analyze electrocardiogram (ECG) signals by adopting chaos-based analysis. This research is going to specifically focus on whether it is possible to use chaos-based analysis of heart rate variability (HRV) signals rather than using chaotic analysis of ECG signals to diagnose OSA. While conventional studies mostly use chaos-based analysis of ECG signals to detect OSA, here, we apply correlation dimension (CD) as a chaotic index to analyze HRV data in OSA patients. For this purpose, 17 patients with OSA and 9 healthy individuals referred to a sleep clinic in Isfahan/Iran are studied, and their HRV time series were extracted from 1-h ECG signals recorded overnight. The preliminary step to calculate CD is phase-space reconstruction of the system based on HRV time series. Corresponding parameters, including embedding dimension and lag time, are estimated optimally using enhanced related methods, and then CD is calculated using Grassberger-Procaccia algorithm. Moreover, to evaluate our results, detrended fluctuation analysis (DFA), one of the well-known nonlinear methods in HRV analysis to detect OSA, is also applied to our data and the result is compared with those obtained from CD analysis of HRV. CD index with P < 0.005 indicates a significant difference in nonlinear dynamics of HRV signals detected from OSA patients and healthy individuals.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...