Related Experiment Video
Updated: Dec 26, 2025

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Estimation of the Effective Dose of Radiation Workers: Optimization Based on the Weight Percentile
1University of Birjand, Physics Department, School of Sciences, Birjand, Iran.
Abstract:
Radiation workers might be exposed to polyenergetic photon radiation beams at different directions in their working environments. In this regard, their effective dose (E) should be accurately estimated using a two-dosimeter algorithm (TDA), based on the measurements of two thermoluminescent dosimeters (TLDs) or film badges that are mounted on the front and back of the body. However, considering different human anatomies, radiation workers may have a variety of weight percentiles. This work sought to find whether TDA obtained for the reference weight percentile (50) can be used for higher weight percentiles (including; 65, 75, 85, and 95). MCNPX was used to simulate different weight percentiles on the revised ORNL phantom by adding extra layers of muscle and adipose on the torso. Then front and back TLD responses were calculated for external beam photon energies of 40 keV to 10 MeV in different irradiation geometries. The results revealed that E value declines with increasing the weight percentile. In this study, three TDA were investigated consisting of Eest = 0.73 Rf + 0.53 Rb (73/53), Eest = 0.55 Rf + 0.50 Rb (55/50), and Eest = 0.70 Rf + 0.30 Rb (70/30). The ratio of Eest/E was calculated for each TDA in different energy bins and weight percentiles. Results obtained using the 55/50 and 70/30 showed higher underestimation for most of the energy bins, especially for PA and AP geometries. Compared to these two TDA, the 73/53 algorithm resulted in higher overestimation for RLAT and LLAT geometries for the same energy bins. Variation of the algorithms showed a similar trend for the studied weight percentiles. To conclude, results obtained by TDA for the 50% weight percentile are applicable for weight percentiles >50%.
More Related Videos
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
Biological Effects of Radiation
Drug Dosing: Obese Patients
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Drug Dosing: Infants and Children
Dose Size and Dosing Frequency: Determination Methods
Dosage Regimens: Partial Pharmacokinetic Parameters