Fabrication of Compressed Hosiery and Measurement of its Pressure Characteristic Exerted on the Lower Limbs
Published on: May 27, 2020
Relationship Between Interface Pressures and Pneumatic Cuff Inflation Pressure at Different Assessment Sites of the
Tjaša Kermavnar1, Kevin J O'Sullivan1, Adam de Eyto1
18808 University of Limerick, Ireland.
Objective:
The aim was to develop a means of predicting interface pressure from cuff inflation pressure during circumferential compression at the lower limb, in order to inform the design of soft exoskeletons.
Background:
Excessive mechanical loading of tissues can cause discomfort and soft tissue injury. Most ergonomic studies on exoskeletons are of interface pressure, but soft exoskeletons apply circumferential pressures similar to tourniquet cuffs by way of cuff inflation pressure. This study details the relationship between interface and cuff inflation pressures for pneumatic tourniquet cuffs.
Method:
Pneumatic cuffs of different widths were inflated to target pressures on (A) a rigid cylinder, (B) the dominant thigh and calf, and (C) knee of healthy participants standing still. Interface pressures were measured under the cuffs using a pressure-sensing mat. Average interface pressures were then compared to cuff inflation pressures. The influence of cuff width, cuff inflation pressure, and participants' anthropometric data on pressure transmission was assessed.
Results:
A strong linear relationship between cuff inflation pressures and interface pressures was observed. Interface pressures were generally higher than cuff inflation pressures. The efficiency of pressure transmission to the lower limb depended on assessment site, adipose tissue thickness, cuff size, cuff inflation pressure, and possibly limb circumference. Regression equations were developed to predict interface pressures at the thigh, calf, and knee.
Conclusion:
Interface pressures under pneumatic cuffs are influenced by the cuff size, cuff inflation pressure, and tissue compressibility. Predicted interface pressure from cuff inflation pressure and vice versa can be used to aid the design of soft exoskeletons.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Assessing Blood pressure in the Leg
Preparation:
Application of Pascal's Law
Hydraulic systems are used to operate automotive brakes, hydraulic jacks, and numerous other mechanical systems. We can derive a relationship between the forces in a simple hydraulic system...
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)