Related Experiment Video
Updated: Dec 26, 2025

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Influence of Sampling Site and Fluid Flow on the Accuracy of Total Body Clearance Calculation
Brandon LaPorte1, Florin Marcel Musteata1
1Albany College of Pharmacy and Health Sciences, Department of Pharmaceutical Sciences, 106 New Scotland Avenue, Albany, New York 12208.
Abstract:
Studies have showed that by assuming arteriovenous drug concentrations are homogenous after intravenous injection, the determination of total body clearance based on venous drug concentrations is often inaccurate. This study considers the use of a fluidic pharmacokinetic profile generator where 28 different profile types were generated corresponding to a physiological model with varying sampling sites, administration locations, and fluid flow rates. Clearance was calculated using established equations, commercial software, and recently proposed models. The results show large differences in clearance values calculated with published equations and commercial software relative to the actual value of clearance. Alterations in sampling site, administration location, and fluid flow rates each influence the extent of calculation errors. The data show that a significant drug concentration gradient exists within the central circulatory system. The results show that the best way to address this issue would be to inject the drug at a peripheral location to allow for sufficient mixing and then sample from a large vein. Extrapolating for missing data can also lead to large errors in clearance calculation; this can be addressed by collecting more samples early after IV bolus administration or by collecting data during steady state conditions for an IV infusion.
More Related Videos
09:00Spatial Measurements of Perfusion, Interstitial Fluid Pressure and Liposomes Accumulation in Solid Tumors
Published on: August 18, 2016
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
Related Concept Videos
Clearance Models: Noncompartmental Models
The noncompartmental approach capitalizes on extensive sampling data, correlating the volume of distribution to systemic exposure and the administered dosage. This method enables...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Typical Model Studies
Conservation of Mass in Fixed, Nondeforming Control Volume
In the case of a sewer pipe, which can be modeled...
Uniform Depth Channel Flow: Problem Solving
Clearance Models: Physiological Models
The organ's clearance rate depends on the blood flow to the organ and the extraction ratio (E). The extraction ratio describes the organ's...