Source-resolved attribution of ground-level ozone formation potential from VOC emissions in Metropolitan Vancouver,

Ying Xiong1, Ke Du1

  • 1Department of Mechanical and Manufacturing Engineering, University of Calgary, Calgary T2N 1N4, Canada.

Related Concept Videos

Boundary Layer Characteristics01:18

Boundary Layer Characteristics

When a fluid encounters a solid surface, a boundary layer forms due to the interaction between the fluid's motion and the stationary surface. This phenomenon is characterized by a thin region adjacent to the surface where viscous forces dominate, influencing the fluid's velocity profile. The development of the boundary layer begins at the leading edge of the surface and evolves as the fluid moves downstream.As the fluid flows over the surface, friction between the fluid and the wall slows down...
454
Volatilization01:10

Volatilization

Volatilization gravimetry is an analytical technique that measures the mass lost due to the volatilization of the substance. This technique is used to estimate the amount of volatile material in a sample. To perform this method, heat a known amount of the sample to a high temperature in a crucible or other suitable vessel. The volatile substance in the sample evaporates, and the vapor is completely expelled from the crucible either by heating the sample or bubbling a stream of inert gas through...
4.4K
Chemical Factors Affecting Respiration Centers01:31

Chemical Factors Affecting Respiration Centers

Chemical factors such as changing CO2, O2, and H+ levels in arterial blood play a critical role in influencing respiration depth and rates. These variations are detected by chemoreceptors—specialized sensors located in two primary body areas. Central chemoreceptors are found throughout the brain stem, including the ventrolateral medulla, while peripheral chemoreceptors are located in the aortic arch and carotid arteries.
CO2 has a potent influence on respiration and is strictly regulated....
1.9K
Measurement of Air Content in Concrete01:23

Measurement of Air Content in Concrete

Air content measurement in concrete is critical for ensuring structural integrity and durability of concrete structures, especially in environments prone to severe weather conditions. Accurate air content analysis optimizes concrete's resistance to freeze-thaw cycles and enhances its workability and strength. Several methods are standardized under ASTM guidelines to measure the air content in fresh concrete, each suitable for different concrete types and conditions.
The pressure method,...
534
Assessment of Ventilation I: Respiratory Rate01:20

Assessment of Ventilation I: Respiratory Rate

Assessment of Ventilation
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
1.8K
Vapor Pressure Lowering03:28

Vapor Pressure Lowering

The equilibrium vapor pressure of a liquid is the pressure exerted by its gaseous phase when vaporization and condensation are occurring at equal rates:
30.4K