Related Experiment Video For CT colonography
Updated: Dec 26, 2025

DUCT: Double Resin Casting followed by Micro-Computed Tomography for 3D Liver Analysis
Published on: September 28, 2021
Electronic cleansing of tagged residue in CT colonography: what radiologists need to know
Thomas Mang1, Christian Bräuer2, Stefaan Gryspeerdt3
1Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Währinger Gürtel 18-20, A-1090, Vienna, Austria. thomas.mang@meduniwien.ac.at.
Abstract:
CT colonography (CTC) is the radiological examination of choice for the diagnosis of colorectal neoplasia. Faecal tagging is considered a mandatory part of bowel preparation. However, the colonic mucosa, obscured by tagged residue, is not accessible to endoluminal 3D views and requires time-consuming 2D evaluation. Electronic cleansing (EC) software algorithms can overcome this limitation by digitally subtracting tagged residue from the colonic lumen. Ideally, this enables a seamless 3D endoluminal evaluation. Despite this benefit, EC is a potential source of a wide range of artefacts. Accurate EC requires proper CTC examination technique and faecal tagging. The digital subtraction process has been shown to affect the relevant morphological features of both colonic anatomy and colonic lesions, if submerged under faecal residue. This article summarises the potential effects of EC on CTC imaging, the consequences for reporting and patient management, and strategies to avoid pitfalls. Furthermore, potentially negative effects on clinical reporting and patient management are shown, and problem-solving techniques, as well as recommendations for the appropriate use of EC techniques, are presented. Radiologists using EC should be familiar with EC-related effects on polyp size and also with correct measurement techniques.
More Related Videos
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Imaging Studies III: Computed Tomography
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Imaging Studies for Cardiovascular System V: CT
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...