Related Experiment Video
Updated: Dec 26, 2025

In Vitro Application of a Wireless Sensor in Flexion-Extension Gap Balance of Unicompartmental Knee Arthroplasty
Published on: May 5, 2023
Aseptic Loosening at the Tibia in Total Knee Arthroplasty: A Function of Cement Mantle Quality?
Chadwick B Hampton1, Zachary P Berliner1, Joseph T Nguyen1
1Adult Reconstruction and Joint Replacement, Hospital for Special Surgery, New York, NY.
Background:
Aseptic loosening remains one of the leading causes for failure of total knee arthroplasty (TKA). We sought to identify early radiographic measures that may associate with aseptic tibial component loosening, emphasizing systematic evaluation of the cement mantle.
Methods:
All TKA revisions from 2007 to 2015 with the primary indication of tibial aseptic loosening were identified using in an institutional implant retrieval database. After exclusion criteria, 61 TKAs comprised the study group. A matched control group of 59 TKAs that had not failed at a minimum of 3 years was identified for comparison. Radiographic analysis on all 6-week postoperative radiographs included angulation of components, cement penetration depth, and presence of radiolucency at the implant-cement and bone-cement interfaces. Groups were compared with Student's t-test, chi-squared test, and Mann-Whitney U-test. A final multivariable logistic regression model was formed for the outcome of aseptic loosening.
Results:
On multivariable analysis, failure was associated with a greater number of zones with cement penetration <2 mm (5.6 vs 3.4 zones, odds ratio [OR] 1.89, P < .001), increasing percent involvement of radiolucency at the implant-cement interface (8.7% vs 3.1%, OR = 1.15, P = .001), and increased varus alignment of the tibial component (1.5° vs 0°, OR = 1.35, P = .014). A greater number of zones with a radiolucent line at the bone-cement interface did not significantly associate (1.1 vs 0.3, P = .091).
Conclusion:
Our results suggest that radiographic indicators of poor cement mantle quality associate with later aseptic loosening. This emphasizes the need for surgeons to perform careful cement technique in order to reduce the risk of TKA failure.
Level Of Evidence:
III (Case-control).
More Related Videos
04:37Author Spotlight: Advancing Research on Candida albicans Biofilm-Associated Prosthetic Joint Infections
Published on: February 2, 2024
06:28Anterior Cruciate Ligament Transection and Synovial Fluid Lavage in a Rodent Model to Study Joint Inflammation and Posttraumatic Osteoarthritis
Published on: September 2, 2025
Related Concept Videos
Soundness of Cement
Porosity in Cement Paste
The balance of water to cement in the mix is...
Mortar Joint Deterioration in Masonry
The...
Hydration of Cement
Fineness of Cement
Direct...
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...