Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
Published on: May 27, 2016
Acute radiation-induced skin toxicity in hypofractionated vs. conventional whole-breast irradiation: An objective,
Leonard Christopher Schmeel1, David Koch1, Frederic Carsten Schmeel2
1Department of Radiation Oncology, University Hospital Bonn, University of Bonn, Germany.
Purpose:
Radiation dermatitis represents one of the most frequent side effects in breast cancer patients undergoing adjuvant whole-breast irradiation (WBI). Whether hypofractionated WBI induces comparable or less acute radiation-induced skin reactions than conventional WBI is still not fully clarified, as randomized evidence and objective assessments are limited. The aim of this study was to objectively determine frequency and severity of acute radiation-induced skin reactions during hypofractionated vs. conventionally fractionated adjuvant WBI.
Methods:
In this randomized multicenter study, a total of 140 breast cancer patients underwent either hypofractionated or conventional WBI following breast-preserving surgery. Maximum radiation dermatitis severity was assessed at completion and during follow-up by physician-assessed CTCAE v4.03 and the patient-reported RISRAS scale. Additionally, photospectrometric skin readings were performed to objectify skin color differences between both treatment arms.
Results:
Radiation dermatitis severity was significantly lower in patients receiving hypofractionation compared with conventional fractionation (mean 1.05 vs. 1.43, p = .024). Grade 0 radiation dermatitis occurred in 21.43% vs. 4.28%, grade ≥2 in 27.14% vs. 42.91% and grade ≥3 in 0% vs. 4.34% of patients following hypofractionated and conventional WBI, respectively. Objective photospectrometric measurements (n = 4200) showed both decreased erythema severity (p = .008) and hyperpigmentation (p = .002) in the hypofractionation arm. Patients allocated to hypofractionated WBI also reported less pain (p = .006), less hyperpigmentation (p = <0.001) and less limitations of day-to-day activities (p = <0.001).
Conclusion:
Physician and patient-assessed toxicity scorings as well as objective photospectrometric skin measurements revealed that hypofractionated WBI yielded lower rates and severity of acute radiation-induced skin toxicity.