Related Experiment Video
Updated: Dec 26, 2025

Author Spotlight: Anterior HR-OCT as a Non-Invasive Tool for Characterizing Ocular Surface Squamous Neoplasia
Published on: August 9, 2024
Topometric and Tomographic Evaluation of Subclinical Keratoconus
Mustafa Koc1, Kemal Tekin2, Hasan Kiziltoprak1
1Ophthalmology Department, Ankara Ulucanlar Eye Training and Research Hospital , Ankara, Turkey.
Purpose:
To investigate the corneal topometric and tomographic findings that can be used in the diagnosis of subclinical keratoconus.
Methods:
A retrospective cohort study. The study group was selected from patients with clinically evident keratoconus in one eye and subclinical keratoconus without evident topographic findings in fellow eye. The age-matched control group was selected from patients who were candidates for laser in situ keratomileusis (LASIK) and did not develop ectasia after LASIK surgery at least 1-year follow-up. All subjects underwent topographic, topometric and tomographic (Belin-Ambrósio Enhanced Ectasia Display III) analyses via a Pentacam HR rotating Scheimpflug camera (Oculus, Germany, version 1.20r.98) before LASIK surgery.
Results:
The study group consisted of 151 patients (69 male and 82 female, mean age of 24.8 ± 7.2 years) and the control group also consisted of 150 patients (70 male and 80 female, mean age of 26.0 ± 6.3 years). There were statistically significant differences in all measured topometric (p˂.05) and tomographic (p˂.001) parameters between the eyes with subclinical keratoconus and those of the control group. In discriminating eyes with subclinical keratoconus from normal eyes, final D showed the highest area under curve value (0.858, sensitivity 85.2%, specificity 66.7%), followed by maximum pachymetric progression index (0.809, sensitivity 81.9%, specificity 69.4%) and average pachymetric progression index (0.796, sensitivity 81.9%, specificity 68.1%) in receiver operating characteristic analysis.
Conclusion:
Topometric and tomographic parameters might be useful for early detection of keratoconus, but the sensitivity and specificity of any parameter are not high enough to be used alone.