Current challenges for shaping the sustainable and mold-free hygienic indoor environment in humid regions

H Wu1,2, J W C Wong1,2

  • 1Department of Biology, Hong Kong Baptist University, Kowloon Tong, Hong Kong Special Administrative Region, China.

Insights

Indoor mold thrives in humidity, impacting health. Current control methods conflict with building sustainability, especially in warm climates, necessitating new strategies.

Area of Science:

  • Environmental Science
  • Building Science
  • Public Health

Background:

  • Indoor mold contamination is a prevalent issue affecting occupant health, particularly in humid regions.
  • Recommended relative humidity (RH) levels for mold prevention are energy-intensive to maintain in tropical/subtropical climates.
  • Building sustainability goals necessitate reduced air conditioning (AC) use, creating a conflict with mold control.

Purpose of the Study:

  • To review current indoor mold control measures.
  • To discuss the limitations of existing strategies.
  • To explore future directions for sustainable mold control.

Main Methods:

  • Literature review of existing mold control strategies.
  • Analysis of the trade-offs between building sustainability and indoor mold hygiene.
  • Discussion of alternative approaches targeting physical environments and surface coatings.

Main Results:

  • Current mold control methods often exhibit limited effectiveness or require significant effort.
  • Maintaining low RH levels (30-60% or <75%) is energy-intensive, especially in warm climates.
  • Alternative strategies show promise but face challenges in widespread adoption and efficacy.

Conclusions:

  • A balance between sustainable building practices and effective indoor mold control is crucial.
  • Further research is needed to develop more sustainable and effective mold inhibition strategies.
  • Climate change may exacerbate indoor mold issues, highlighting the urgency for innovative solutions.

Related Concept Videos

Masonry in Cold and Hot Weather Conditions01:21

Masonry in Cold and Hot Weather Conditions

In cold weather, masonry construction requires specific precautions to ensure mortar does not freeze before curing, as this can significantly weaken its strength and watertightness. Mortar temperature should be maintained between 60°F and 80°F to support proper hydration and curing. Below 40°F, mortar water must be heated, but should not exceed 120°F as high temperatures can reduce mortar's compressive and bond strength.
Other key practices include keeping masonry units...
287
Methods for Controlling Microbial Growth01:29

Methods for Controlling Microbial Growth

Microbial growth control refers to various methods employed to inhibit, reduce, or eliminate microorganisms to ensure safety and hygiene across different settings. These methods are categorized based on the target environment and the level of microbial control required.Biocides are versatile agents designed to control microorganisms by either inhibiting their growth or outright killing them. These agents work through various physical, chemical, mechanical, or biological mechanisms. The...
1.4K
Key Techniques in Microbiology01:19

Key Techniques in Microbiology

Aseptic techniques prevent contamination, ensure experimental accuracy, and protect researchers and microbial cultures. These techniques are essential in clinical, industrial, and research settings where sterility is required.Maintaining Sterility in Laboratory PracticesScientists maintain sterility by sterilizing tools with heat or chemicals, disinfecting work surfaces, and handling cultures in controlled environments. Working near an open flame or within a laminar flow hood reduces the risk...
1.3K
Surface Membrane Barriers01:18

Surface Membrane Barriers

The skin and mucous membranes serve as the primary line of defense against pathogens by providing both physical and chemical protection. These barriers are essential in preventing the entry and establishment of microbes, thereby maintaining the integrity of the host.
The outer layer of the skin, the epidermis, is a robust barrier comprising layers of closely packed keratinized cells. This dense arrangement prevents microbes from penetrating the body. The periodic shedding of epidermal cells...
2.5K
Curing Methods01:26

Curing Methods

Concrete members with a small surface-to-volume ratio are cured by oiling and moistening the forms before casting the concrete member. These forms can be left in place for a prolonged period to prevent moisture loss, and can be wetted if made of a material suitable for wetting. If the forms are removed early, the concrete member is moistened and covered with polythene sheets to maintain moisture. For large horizontal concrete surfaces exposed to dry weather, a temporary covering is suspended...
232
Waterproofing and Anti-Bacterial Admixtures in Concrete01:22

Waterproofing and Anti-Bacterial Admixtures in Concrete

Concrete's susceptibility to water absorption is due to the capillary action within the pores of its hydrated cement paste. This action draws water in, creating the need for waterproofing admixtures to prevent such penetration. The efficacy of these admixtures is contingent upon the water pressure, with variations arising from different conditions such as rain, capillary rise, or hydrostatic pressure in structures intended to hold water.
Waterproofing admixtures render concrete hydrophobic,...
193