Related Experiment Video
Updated: Dec 26, 2025

Disposable Dosators for Pulmonary Insufflation of Therapeutic Agents to Small Animals
Published on: March 30, 2017
Evaluation of a Novel Prototype for Pressurized Intraperitoneal Aerosol Chemotherapy
Hee Su Lee1, Junsik Kim1, Eun Ji Lee2
1Interdisciplinary Program in Bioengineering, Seoul National University Graduate School, Seoul 08826, Republic of Korea.
Abstract:
Pressurized intraperitoneal aerosol chemotherapy (PIPAC) has been suggested as an alternative option for treating peritoneal carcinomatosis (PC). Even with its clinical advantages, the current PIPAC system still suffers from limitations regarding drug distribution area and penetration depth. Thus, we evaluated the new PIPAC system using a novel prototype, and compared its performance to the results from previous studies related with the current MIP® indirectly because the system is currently not available for purchase in the market. The developed prototype includes a syringe pump, a nozzle, and controllers. Drug distribution was conducted using a methylene blue solution for performance test. For penetration depth evaluation, an ex-vivo experiment was performed with porcine tissues in a 3.5 L plastic box. Doxorubicin was sprayed using the novel prototype, and its penetration depth was investigated by confocal laser scanning microscopy. The experiment was repeated with varying nozzle levels from the bottom. The novel prototype sprays approximately 30 μm drug droplets at a flow rate of 30 mL/min with 7 bars of pressure. The average diameter of sprayed region with concentrated dye was 18.5 ± 1.2 cm, which was comparable to that of the current MIP® (about 10 cm). The depth of concentrated diffusion (DCD) did not differ among varying nozzle levels, whereas the depth of maximal diffusion (DMD) decreased with increasing distance between the prototype and the bottom (mean values, 515.3 μm at 2 cm; 437.6 μm at 4 cm; 363.2 μm at 8 cm), which was comparable to those of the current MIP® (about 350-500 μm). We developed a novel prototype that generate small droplets for drug aerosolization and that have a comparably wide sprayed area and depth of penetration to the current MIP® at a lower pressure.
More Related Videos
04:04Endobronchial Ultrasound-guided Intratumoral Injection of Cisplatin for the Treatment of Isolated Mediastinal Recurrence of Lung Cancer
Published on: February 12, 2017
04:59Author Spotlight: Developing a Disposable Dosator for Preclinical Testing of Dry Powder Inhalers in Small Animal Models
Published on: August 18, 2023