[Evaluation of a measurement tool with real-time display of the standard value for fetal biometrics]
L Maretti-Reheis1, F Séverac2, R Favre1
1Service de gynécologie obstétrique, hôpitaux universitaires de Strasbourg, avenue Molière, BP 426, 67091 Strasbourg cedex, France.
Objectives:
Most of the ultrasound machines include a tool allowing real-time display of the standard value of the biometric measurement being taken. Our hypothesis was that this tool influences the sonographer as measurements are taken, by inducing a normalization, thus a tendency towards the 50th percentile. The objective of this study was to evaluate the impact of a real-time display of the standard value in prenatal ultrasound screening.
Methods:
We conducted an observational, prospective, controlled and open study including all patients who underwent a prenatal ultrasound scan in the 2nd or 3rd trimester at the University Hospitals in Strasbourg between December 2017 and June 2018. Exclusion criteria were the presence of a fetal morphological abnormality or a karyotypic abnormality. The tool being tested was the real-time display on screen of the gestational age, of which the measurement corresponds to the 50th percentile. The measurements were retrospectively transformed into Z-scores. The main end-point was to compare the distribution of Z-scores between the groups.
Results:
We included 3551 ultrasound examinations: 696 performed with the tool and 2796 performed without. Fifty-nine scans were excluded due to morphological abnormalities. There was no statistically significant difference between the Z-scores distributions of measurements performed with or without the tool, regardless of the parameter studied. There was also no difference in the detection of pathological measurements: below the 10th percentile or above the 90th percentile.
Conclusion:
The use of such a tool does not seem to be detrimental to biometric screening, but on the other hand does not seem useful either.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Measurement of Blood Pressure
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...