[Heart catheter dislocation following ventriculo-atrial cerebrospinal fluid drainage. Report of 2 cases]

H Voss1, G Sandvoss

  • 1Fachbereich Neurochirurgie, Krankenhaus Ludmillenstift Meppen.

Der Anaesthesist
|December 1, 1988
PubMed

Insights

Ventriculo-atrial shunt systems for hydrocephalus can lead to cardiac catheter dislocation. A chest X-ray after central venous catheter removal is recommended to detect this complication.

Area of Science:

  • Neurosurgery
  • Cardiology
  • Radiology

Background:

  • Ventriculo-atrial shunt systems are a common treatment for hydrocephalus internus.
  • Central venous catheters are often introduced via the left subclavian vein for these procedures.

Observation:

  • Two cases of cardiac catheter dislocation following adjustment or removal of central venous catheters are presented.
  • Dislocation occurred after manipulation of catheters introduced through the left subclavian vein.

Findings:

  • Technical and pathophysiological factors can predispose to cardiac catheter dislocation.
  • Ventriculo-peritoneal drainage may be an alternative to avoid this complication.

Implications:

  • Post-removal chest X-rays are crucial for detecting cardiac catheter dislocation in patients with ventriculo-atrial shunts.
  • Awareness of these risks can improve patient safety and management strategies.