Related Experiment Video
Updated: Dec 26, 2025

Evaluation of a Point-of-Care Testing Analyzer for Measuring Peripheral Blood Leukocytes
Published on: March 22, 2022
Evaluation of the Element point-of-care blood gas analyzer for use in horses
Clarisa R Krueger1, Eileen S Hackett1, Ann M Hess2
1Department of Clinical Sciences, Colorado State University, Fort Collins, CO.
Objective:
To compare the Element point-of-care (POC) portable blood gas analyzer with a laboratory-based bench-top reference analyzer using whole blood samples obtained from horses presenting to a referral center with various disorders in order to determine agreement between these analyzers.
Design:
Prospective clinical study.
Setting:
The study was conducted at a university teaching hospital at moderate altitude.
Animals:
One hundred paired samples from 80 horses >1 year of age were collected after obtaining informed client consent. Fifty paired samples were from patients admitted for elective procedures and considered to be healthy, and 50 paired samples were emergency admissions and considered to be critically ill.
Measurements And Main Results:
Paired whole blood samples were evaluated on both the Element POC and Radiometer ABL 800 FLEX analyzers simultaneously, and results were compared. Pearson correlation coefficients between analyzers were calculated. To assess agreement, scatter and Bland-Altman plots were evaluated, and mean difference and 95% limits of agreement were calculated for each analyte. Correlation was either good (0.8-0.92) or excellent (>0.93) for the majority of analytes. All analytes apart from hemoglobin had acceptable agreement, with ≥80% of individual results within agreement targets. Precision targets were acceptable for most analytes, with partial pressure of carbon dioxide (pCO2 ) and calcium (Ca2+ ) exceeding precision targets.
Conclusions:
The portable Element POC system had acceptable agreement with the ABL 800 FLEX bench-top analyzer currently in use at the study center when evaluating the majority of analytes from equine whole blood samples.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
Related Concept Videos
Blood Studies I: ABG and VBG
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...