Comparison of tissue oxygenation achieved breathing oxygen using different delivery devices and flow rates
Denise F Blake1,2,3, Melissa Crowe4, Daniel Lindsay5
1Emergency Department, The Townsville Hospital, Townsville, Queensland, Australia.
Introduction:
Divers with suspected decompression illness require high concentration oxygen (O₂). There are many different O₂ delivery devices, with few data comparing their performance. This study evaluated O₂ delivery, using tissue O₂ partial pressure (PtcO₂), in healthy divers breathing O₂ via three different delivery devices.
Methods:
Twelve divers had PtcO₂ measured at six limb sites. Participants breathed O₂ from: a demand valve using an intraoral mask with a nose clip (NC); a medical O₂ rebreathing system (MORS) with an oronasal mask and with an intraoral mask; and a non-rebreather mask (NRB) at 15 or 10 L·min⁻¹ O₂ flow. In-line inspired O₂ FIO₂) and nasopharyngeal FIO₂ were measured. Participants provided subjective ratings of device comfort, ease of breathing, and overall ease of use.
Results:
PtcO₂ values and nasopharyngeal FIO₂ were similar with the demand valve with intraoral mask, MORS with both masks and the NRB at 15 L·min⁻¹. PtcO₂ and nasopharyngeal FIO₂ values were significantly lower with the NRB at 10 L·min⁻¹. The NRB was rated as the most comfortable to wear, easiest to breathe with, and overall the easiest to use.
Conclusion:
Of the commonly available devices promoted for O₂ delivery to injured divers, similar PtcO₂ and nasopharyngeal FIO₂ values were obtained with the three devices tested: MORS with an oronasal or intraoral mask, demand valve with an intraoral mask and NRB at a flow rate of 15 L·min⁻¹. PtcO₂ and nasopharyngeal FIO₂ values were significantly lower when the flow rate using the NRB was decreased to 10 L·min⁻¹.
More Related Videos
12:29Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes: