Background:
Multiple approaches for fixation of distal radius fractures exist; nonetheless, there is no consensus on the optimal treatment for these injuries. Although using volar locking plates has become increasingly common as a surgical intervention, the usefulness of bone augmentation remains debatable. Therefore, this study aimed to evaluate the necessity of bone augmentation for distal radius fractures fixed with a volar locking plate.
Methods:
This retrospective study enrolled patients with a single distal radius fracture treated with a volar locking plate between January 2014 and December 2016. Overall, 105 fractures were included and divided into two groups (non-bone augmentation: group 1, n = 88; bone augmentation: group 2, n = 17). Images were reviewed, and dorsal cortex collapse, volar tilting, and radial height and inclination were measured immediately after surgery and at the 6-month follow-up.
Results:
Both groups exhibited significant differences in dorsal collapse (p < 0.001 and p = 0.001, respectively) and radial height shortening (p < 0.001 and p = 0.039, respectively); volar tilting and radial inclination did not differ significantly. There was no difference in the degree of dorsal collapse (p = 0.715) and radial height shortening (p = 0.651) between the two groups. Of the 105 fractures, 54 were identified as comminuted type according to the AO classification (A3, C2, and C3), and similar radiographic outcomes were noted.
Conclusions:
Volar locking plates for the treatment of distal radius fractures with or without bone augmentation do not affect the radiographic outcomes. In comminuted fractures, additional bone augmentation is unnecessary if intraoperative anatomical reduction and fixation are performed when possible.