Related Experiment Video
Updated: Dec 25, 2025

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Noninvasive cardiac output measurement based optimization in nonresponders of cardiac resynchronization therapy
Mustafa Yenerçağ1, Serkan Yüksel2, Metin Çoksevim2
1Department of Cardiology, University of Health Sciences, Samsun Training and Research Hospital, Samsun, Turkey.
Background:
Cardiac resynchronization therapy (CRT) is an important and effective therapy for end-stage heart failure (HF). Nonresponse to CRT is one of the main obstacles to its application in clinical practice. Herein, we investigated the utilization of the optimization technique using noninvasive cardiac output measurement (NICOM) based Mobil-O-Graph device that measures several circulation parameters noninvasively.
Methods:
Seventy-five CRT nonresponder HF patients with an implanted CRT device were included. Patients were randomized equally to 3 groups: NICOM, echocardiographic, and empirical optimization groups. After 3 months of optimization, changes in six minutes walk test (6-MWT), cardiac output (CO), left ventricular ejection fraction (LVEF), and end-systolic volume (LVESV) were measured. New York Heart Association (NYHA) class and hospitalization for HF were also determined.
Results:
There were no statistically significant differences among the three groups in terms of demographics, baseline characteristics. In the NICOM group, the 6-MWT, LVEF, CO, and LVESV measurements showed significant improvements compared to baseline values (P < .05). There was no significant improvement in 6-MWT, LVEF, CO, NYHA class, and LVESV in Echo and Empirical groups after 3 months (P > .05). 6-MWT, CO, LVESV percentages, and hospitalization for HF were significantly different between the groups (P < .05). In post hoc analyzes, the percentages of the change in 6-MWT, CO, LVESV, and hospitalization for HF were significantly higher in the NICOM group (P < .017).
Conclusions:
This study suggests that Mobil-O-Graph device optimization according to CO measures does appear to have potential hemodynamic and clinical benefits in nonresponder CRT patients. Use of Mobil-O-Graph device as an option for optimization of CRT devices can be an attractive method of improving CRT outcomes.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
08:35Oxygenation-sensitive Cardiac MRI with Vasoactive Breathing Maneuvers for the Non-invasive Assessment of Coronary Microvascular Dysfunction
Published on: August 17, 2022
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...