Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Glaucoma: Overview01:25

Glaucoma: Overview

1.1K
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
1.1K
Open Angle Glaucoma: Treatment01:27

Open Angle Glaucoma: Treatment

891
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
891
Angle Closure Glaucoma: Treatment01:28

Angle Closure Glaucoma: Treatment

1.0K
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
1.0K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Impact of visit schedule on estimated success rates in glaucoma surgical studies.

The British journal of ophthalmology·2026
Same author

A vision transformer model for the detection of glaucoma from optic disc photographs.

Scientific reports·2026
Same author

Detection of Structural Glaucoma Progression with Deep Learning on Serial Optic Disc Photographs.

Ophthalmology. Glaucoma·2026
Same author

Fibrous ingrowth: an overlooked cause of Ahmed Glaucoma Valve failure.

Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie·2026
Same author

The Incidence of Clinically Significant Hypotony After Trabeculectomy.

Journal of glaucoma·2026
Same author

DINO-EYE: self-supervised learning for identification of different optic disc phenotypes in primary open angle glaucoma.

Scientific reports·2026

Related Experiment Video

Updated: Dec 25, 2025

Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo
08:17

Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo

Published on: September 22, 2017

19.9K

Macular imaging with optical coherence tomography in glaucoma.

Vahid Mohammadzadeh1, Nima Fatehi2, Adeleh Yarmohammadi3

  • 1Glaucoma Division, Stein Eye Institute, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, California, USA.

Survey of Ophthalmology
|March 23, 2020
PubMed
Summary

Spectral-domain optical coherence tomography (SD-OCT) of the macula is a powerful tool for detecting early glaucoma. This imaging technique offers high reproducibility and is increasingly vital for monitoring glaucoma progression.

Keywords:
OCTdetectionglaucomaimagingmaculaoptical coherence tomographyprogressionstructure-functionvariability

More Related Videos

Using Optical Coherence Tomography and Optokinetic Response As Structural and Functional Visual System Readouts in Mice and Rats
07:08

Using Optical Coherence Tomography and Optokinetic Response As Structural and Functional Visual System Readouts in Mice and Rats

Published on: January 10, 2019

10.5K
Application of Optical Coherence Tomography to a Mouse Model of Retinopathy
08:22

Application of Optical Coherence Tomography to a Mouse Model of Retinopathy

Published on: January 12, 2022

5.0K

Related Experiment Videos

Last Updated: Dec 25, 2025

Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo
08:17

Optical Coherence Tomography: Imaging Mouse Retinal Ganglion Cells In Vivo

Published on: September 22, 2017

19.9K
Using Optical Coherence Tomography and Optokinetic Response As Structural and Functional Visual System Readouts in Mice and Rats
07:08

Using Optical Coherence Tomography and Optokinetic Response As Structural and Functional Visual System Readouts in Mice and Rats

Published on: January 10, 2019

10.5K
Application of Optical Coherence Tomography to a Mouse Model of Retinopathy
08:22

Application of Optical Coherence Tomography to a Mouse Model of Retinopathy

Published on: January 12, 2022

5.0K

Area of Science:

  • Ophthalmology
  • Medical Imaging
  • Glaucoma Research

Background:

  • Spectral-domain optical coherence tomography (SD-OCT) enables rapid imaging of posterior eye segments.
  • Key anatomical areas include the optic nerve head, circumpapillary retinal nerve fiber layer, and macula.

Purpose of the Study:

  • To review the role of macular SD-OCT in glaucoma diagnosis and management.
  • To highlight emerging diagnostic applications of macular SD-OCT in ophthalmology.

Main Methods:

  • Comprehensive literature review focusing on macular SD-OCT in glaucoma.
  • Analysis of evidence supporting SD-OCT for early glaucoma detection and progression monitoring.

Main Results:

  • Ample evidence supports macular SD-OCT for early glaucoma detection.
  • Macular SD-OCT measurements show high reproducibility.
  • Accumulating evidence demonstrates utility in tracking glaucoma progression.

Conclusions:

  • Macular SD-OCT is an essential diagnostic tool in modern glaucoma care.
  • Its application extends from early detection to monitoring disease advancement.