Related Experiment Video
Updated: Dec 25, 2025

Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Are Automated Office Blood Pressure Readings More Variable Than Home Readings?
Martin G Myers1, Janusz Kaczorowski2
1From the Schulich Heart Program, Sunnybrook Health Sciences Centre, and the Department of Medicine, University of Toronto (M.G.M.).
Abstract:
A recent report from the American Heart Association stated that automated office blood pressure (AOBP) is preferred for evaluating office blood pressure (BP) because it is more accurate and devoid of white coat effect, which is mostly caused by higher systolic BP readings. However, AOBP has been criticized for being too variable to be used for identifying patients with possible hypertension. We, therefore, compared AOBP with home BP monitoring (HBPM) with respect to variability as determined by their relationship with the gold standard for determining BP status, awake ambulatory BP (ABP). The main focus was on systolic BP. Data on AOBP, HBPM, and awake ABP were collected on 300 patients referred from the community for 24-hour ambulatory BP monitoring. The SD of the difference between mean systolic awake ABP (136.4±11.5) and AOBP (131.2±15.7) was 13.6 mm Hg compared with 13.1 for the SD of the difference (P=0.52) between the systolic awake ABP and the HBPM (136.7±16.1). Coefficients of correlation were slightly lower for systolic awake ABP versus AOBP (r=0.54) compared with HBPM (r=0.60). Coefficients of variation for AOBP (12.0%) and HBPM (11.8%) and variances between AOBP and HBPM were similar. Of the 139 patients with hypertension as defined by a manual office systolic BP ≥140 mm Hg, variability in BP readings as determined by the SDs of the mean difference versus awake ABP were similar (P=0.56) for AOBP (14.6) and HBPM (13.9). Overall, both systolic AOBP and HBPM exhibited a similar degree of variability as assessed by the various methods.
More Related Videos
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
09:18Author Spotlight: Assessing the Reliability of Doppler Ultrasound in Measuring Leg Blood Flow
Published on: December 15, 2023
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pre-Procedural Guidelines for Assessing Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure