Multiple solid phase microextraction combined with ambient mass spectrometry for rapid and sensitive detection of
Chin-Hsiung Wang1, Hung Su1, Jo-Han Chou2
1Department of Chemistry, National Sun Yat-Sen University, Kaohsiung, Taiwan.
Abstract:
Multiple solid phase microextraction (mSPME) combined with thermal desorption-electrospray ionization/mass spectrometry (TD-ESI/MS) was developed to rapidly characterize trace analytes in aqueous solution. A number of commercial available SPME fibers (from 2 to 10 fibers) were simultaneously used for extracting the analytes in solution. The fibers were then bundled together on a holder and subjected for the ambient mass spectrometric analysis. Good linearity for calibration (R2 = 0.9995) and low limit of quantification (<1 ppb) were achieved by using 10 SPME fibers coated with polyacrylate (PA) to extract bisphenol A. It was also found that the analyte signals increased with the number of SPME fibers for extraction. Uncontroversial, a shorter extraction time was required by using mSPME to reach the same level of analyte signal as that by using single SPME fiber for a longer extraction time. Trace bisphenol A (4-20 ppb) in the polycarbonate (PC) baby milk bottles was rapidly detected using mSPME-TD-ESI/MS and the analysis was completed within 1 min. The use of multiple SPME fibers coated with different materials enable the concentration of different type of analytes in the solution. Ibuprofen, bisphenol A (BPA), and 4-n-nonylphenol (4-n-NP) were simultaneously detected by using PA and polydimethylsiloxane (PDMS) coated fibers for extraction.
More Related Videos
09:42Fabrication of a Dipole-assisted Solid Phase Extraction Microchip for Trace Metal Analysis in Water Samples
Published on: August 7, 2016
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....