Heteroleptic Pt(II)-dithiolene-based Colorimetric Chemosensors: Selectivity Control for Hg(II) Ion Sensing
Hyokyung Jeon1, Hwahui Ryu1, Inho Nam2
1Department of Chemistry, Seoul Women's University, Seoul 01797, Korea.
Abstract:
Hg2+ ions can accumulate in the natural environment and in organisms, where they cause damage to the central nervous system. Therefore, the detection of Hg2+ ions is essential for monitoring environmental contamination and human health. Herein, we demonstrate a simple method for tuning chemosensor signal ratios that significantly increased chemosensor selectivity for Hg2+ detection. Selectivity tuning was accomplished for chemosensors of the type (diphosphine)Pt(dmit), bearing the two different terminal groups 1,2-bis(diphenylphosphino)ethane (dppe) and 1,2-bis[bis(pentafluorophenyl)phosphino]ethane) (dfppe) due to the modulation of specific intermolecular interactions between the dmit ligand and Hg2+ ion. The structure exhibited a large pseudo-Stokes shift, which was advantageous for the internal reference signal and for eliminating potential artifacts. Straightforward chain-end manipulation enabled the tuning of chemosensor properties without additional chemical alterations. Based on these findings, we propose a new platform for improving the selectivity and sensitivity of colorimetric cation sensors. The results of this study will facilitate the designing of organic materials whose certain properties can be enhanced through precise control of the materials' chemical hybridization by simple functional end-group manipulation.
Related Concept Videos
Indicators
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Complexometric Titration: Overview
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
EDTA: Chemistry and Properties
Complexometric Titration: Ligands