Related Experiment Video
Updated: Dec 25, 2025

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
Published on: November 23, 2019
Can C7 Slope Be Used as a Substitute for T1 Slope? A Radiographic Analysis
Ivan B Ye1, Ray Tang1, Zoe B Cheung1
1Icahn School of Medicine at Mount Sinai, New York, NY, USA.
Study Design:
Retrospective radiographic study.
Objectives:
T1 slope is an important parameter of sagittal spinal balance. However, the T1 superior endplate can be difficult to visualize on radiographs due to overlying anatomical structures. C7 slope has been proposed as a potential substitute for T1 slope when the T1 superior endplate is not well visualized. The objective of this study was 2-fold: (1) to assess the correlation between C7 and T1 slopes on upright cervical spine radiographs and (2) to evaluate the interrater reliability of C7 slope.
Methods:
Cervical spine radiographs taken between December 2017 and June 2018 at a single institution were reviewed. Two observers measured upper C7 slope, lower C7 slope, and T1 slope. The correlations between upper and lower C7 slope and T1 slope were evaluated, and linear regression analyses were performed. Interrater reliability of C7 slope was also assessed.
Results:
In this cohort of 152 patients, there was a strong correlation between upper C7 slope and T1 slope (r = 0.91, P < .001), as well as between lower C7 slope and T1 slope (r = 0.90, P < .001). T1 slope could be estimated from the linear regression equation, T1 slope = 0.87 × C7 slope + 7, with an overall model fit of R 2 = 0.8. There was strong interrater reliability for upper (intraclass correlation coefficient [ICC] = 0.95, P < .001) and lower C7 slope (ICC = 0.96, P < .001).
Conclusions:
Both the upper and lower C7 slope are strongly correlated with T1 slope and can be used as a substitute to estimate T1 slope when the superior endplate of T1 is not well visualized.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
07:56Scanning Skeletal Remains for Bone Mineral Density in Forensic Contexts
Published on: January 29, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
X-ray Imaging
Radiological Investigation I: X-ray and CT