Related Experiment Video
Updated: Dec 25, 2025

Plasmonic Photothermal Cancer Therapy: Nanoparticle-embedded Tumor-tissue-mimicking Phantoms for Visualizing Photothermal Temperature Distribution
Published on: May 9, 2025
Accurate and Real-Time Temperature Monitoring during MR Imaging Guided PTT
Xianfu Meng1, Boyu Zhang2, Yan Yi1
1Shanghai Key Laboratory of Green Chemistry and Chemical Processes, School of Chemistry and Molecular Engineering, East China Normal University, Shanghai 200062, China.
Abstract:
Photothermal therapy (PTT) is an efficient approach for cancer treatment. However, accurately monitoring the spatial distribution of photothermal transducing agents (PTAs) and mapping the real-time temperature change in tumor and peritumoral normal tissue remain a huge challenge. Here, we propose an innovative strategy to integrate T1-MRI for precisely tracking PTAs with magnetic resonance temperature imaging (MRTI) for real-time monitoring temperature change in vivo during PTT. NaBiF4: Gd@PDA@PEG nanomaterials were synthesized with favorable T1-weighted performance to target tumor and localize PTAs. The extremely weak susceptibility (1.04 × 10-6 emu g-1 Oe1-) of NaBiF4: Gd@PDA@PEG interferes with the local phase marginally, which maintains the capability of MRTI to dynamically record real-time temperature change in tumor and peritumoral normal tissue. The time resolution is 19 s per frame, and the detection precision of temperature change is approximately 0.1 K. The approach achieving PTT guided by multimode MRI holds significant potential for the clinical application.
More Related Videos
13:41Magnetic Resonance-Guided High Intensity Focused Ultrasound Generated Hyperthermia: A Feasible Treatment Method in a Murine Rhabdomyosarcoma Model
Published on: January 13, 2023
09:01Magnetic-, Acoustic-, and Optical-Triple-Responsive Microbubbles for Magnetic Hyperthermia and Pothotothermal Combination Cancer Therapy
Published on: May 22, 2020
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...