Related Experiment Video
Updated: Dec 25, 2025

Comprehensive Endovascular and Open Surgical Management of Cerebral Arteriovenous Malformations
Published on: October 20, 2017
A comparison of arterial spin labelling with catheter angiography in evaluating arteriovenous malformations: a
Sanjeev Ramachandran1,2, Deyashini Mukherjee1,2, Jonathan Delf1
1University Hospitals of Leicester NHS Trust, Leicester, United Kingdom.
Objectives:
To compare the performance of arterial spin labelling (ASL) in evaluating arteriovenous malformations (AVMs) against the current gold standard of catheter angiography.
Methods:
We systematically reviewed the published literature using EMBASE and Medline. We included studies that compared ASL to catheter angiography in the assessment of AVMs in three outcome domains: detection, angioarchitectural and haemodynamic features.
Results:
From 314 unique citations, 19 studies representing 289 patients with intracranial AVMs met our inclusion criteria. We did not pool data due to marked heterogeneity in study outcome measures. Seven studies showed high diagnostic performance of ASL in identifying arterial feeders, with sensitivity ranging from 84.6 to 100% and specificity ranging from 93.3 to 100%. Six studies showed strong ability in detecting arteriovenous shunting, with sensitivity ranging from 91.7 to 100% and specificity ranging from 90 to 100%. Seven studies demonstrated that ASL could identify nidal location and size as well as catheter angiography, while five studies showed relatively poorer performance in delineating venous drainage. Two studies showed 100% sensitivity of ASL in the identification of residual or obliterated AVMs following stereotactic radiosurgery.
Conclusions:
Despite limitations in the current evidence base and technical challenges, this review suggests that ASL has a promising role in the work-up and post-treatment follow-up of AVMs. Larger scale prospective studies assessing the diagnostic performance of ASL are warranted.
Advances In Knowledge:
ASL demonstrates overall validity in the evaluation of intracranial AVMs.
More Related Videos
12:29Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
05:23Author Spotlight: Noninvasive Cerebral Blood Flow Determination in Human Functional Brain Region for Diagnosis of Neurological Disorders
Published on: May 31, 2024
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation