Related Experiment Video
Updated: Dec 25, 2025

Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024
Cost-effectiveness analysis of two attachment systems for mandibular overdenture
Carine Matthys1, William De Vijlder2, Jos Besseler3
1Clinic for Removable Prosthodontics, Faculty of Medicine and Health Sciences, Dental School, Ghent University, Ghent, Belgium.
The cylindrical (Group L) attachment for 2-implant overdentures (2IOD) is more cost-effective than the spherical (Group D) attachment over a 5-year period. This analysis aids stakeholders in choosing the optimal mandibular 2IOD treatment option.
Area of Science:
- Dental prosthetics
- Health economics
- Evidence-based dentistry
Background:
- Cost-effectiveness analysis is crucial for stakeholders in dental treatment decisions.
- Edentulous mandibles can be effectively restored with 2-implant overdentures (2IOD).
- Attachment systems significantly influence the overall cost and patient well-being of 2IODs.
Purpose of the Study:
- To compare the cost-effectiveness of two different attachment systems for mandibular 2-implant overdentures (2IOD).
- To evaluate patient well-being and treatment costs over a 5-year period.
- To provide data for informed decision-making for patients, clinicians, and payers.
Main Methods:
- A 5-year prospective study involving 116 patients with mandibular 2IODs using spherical (Group D) and cylindrical (Group L) attachments.
- Patient well-being assessed using OHIP-14-Total (OHIP-14-T).
- Cost-effectiveness analysis incorporating initial and maintenance costs, discounted at 4% and 1.5%, with sensitivity analysis via bootstrapping.
Main Results:
- The cylindrical attachment (Group L) demonstrated a higher health effect (8.54) compared to the spherical attachment (Group D) (6.36).
- The total discounted costs over 5 years were lower for Group L (EUR 3,840.62) than for Group D (EUR 4,210.98).
- Bootstrap analysis confirmed that the cylindrical attachment (Group L) dominates the spherical attachment (Group D) in cost-effectiveness.
Conclusions:
- The 2-implant overdenture (2IOD) with the cylindrical (L) abutment is the dominant, more cost-effective option compared to the spherical (D) abutment over a 5-year period.
- This finding supports the selection of cylindrical attachments for mandibular 2IODs to optimize patient outcomes and resource allocation.