Related Experiment Video
Updated: Dec 25, 2025

Spin Saturation Transfer Difference NMR SSTD NMR: A New Tool to Obtain Kinetic Parameters of Chemical Exchange Processes
Published on: November 12, 2016
Spin-flip approach within time-dependent density functional tight-binding method: Theory and applications
Mayu Inamori1, Takeshi Yoshikawa2, Yasuhiro Ikabata2
1Department of Chemistry and Biochemistry, School of Advanced Science and Engineering, Waseda University, Tokyo, Japan.
Abstract:
A spin-flip time-dependent density functional tight-binding (SF-TDDFTB) method is developed that describes target states as spin-flipping excitation from a high-spin reference state obtained by the spin-restricted open shell treatment. Furthermore, the SF-TDDFTB formulation is extended to long-range correction (LC), denoted as SF-TDLCDFTB. The LC technique corrects the overdelocalization of electron density in systems such as charge-transfer systems, which is typically found in conventional DFTB calculations as well as density functional theory calculations using pure functionals. The numerical assessment of the SF-TDDFTB method shows smooth potential curves for the bond dissociation of hydrogen fluoride and the double-bond rotation of ethylene and the double-cone shape of H3 as the simplest degenerate systems. In addition, numerical assessments of SF-TDDFTB and SF-TDLCDFTB for 39 S0 /S1 minimum energy conical intersection (MECI) structures are performed. The SF-TDDFTB and SF-TDLCDFTB methods drastically reduce the computational cost with accuracy for MECI structures compared with SF-TDDFT.
More Related Videos
Related Concept Videos
Spin–Spin Coupling Constant: Overview
Qualitatively, any spin plus-half nucleus polarizes the spins of its electrons to the minus-half state. Consequently, the paired electron in the hydrogen–carbon bond must...
Spin–Spin Coupling: One-Bond Coupling
Valence Bond Theory
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the involved orbitals. The...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Atomic Nuclei: Nuclear Spin State Population Distribution

