A survey on radiation exposure reduction methods including rectangular collimation for intraoral radiography by
Background:
The authors conducted a survey of the American Academy of Pediatric Dentistry (AAPD) to determine awareness of the Image Gently Campaign in Dentistry (IGCD) and to ascertain radiologic practices, including radiation dose-reduction strategies such as rectangular collimation.
Methods:
An institutional review board approved an electronic survey sent to 7,087 AAPD members covering practitioner demographic characteristics, radiographic techniques, and dose-reduction practices, including rectangular collimation. Responses were tabulated and analyzed using binomial tests, χ2 tests, and Fisher exact tests.
Results:
A total of 1,124 pediatric dentists or residents in pediatric dentistry responded, (response rate 16%, margin of error ± 2.7%). The largest group (23.8%) graduated after 2010. More than 90% indicated that they followed American Dental Association (ADA)-AAPD radiation exposure guidelines, but only 33.5% were aware of IGCD. Almost all respondents used direct digital systems, storage phosphor plates, or both. Only 22.3% (n = 220) used rectangular collimation. Nonusers indicated that they were unfamiliar with collimation (33.3%) or concerned about potential for increased cone cuts (30.2%), 11.6% of respondents were unaware of any regulatory requirements for inspections of radiographic equipment recurring at regular intervals, and 4.1% of respondents considered use of lead aprons optional.
Conclusions:
Although the pediatric dentists surveyed believe they are in compliance with ADA-AAPD guidelines, most are unaware of IGCD recommendations. Use of digital radiography is almost ubiquitous, but use of rectangular collimation is limited.
Practice Implications:
Dentists treating children should be familiar with ADA-AAPD radiation exposure guidelines and should consider using the dose-reduction strategies recommended by IGCD.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
X-ray Imaging
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...