Related Experiment Video
Updated: Dec 25, 2025

Laparoscopic-Assisted Seldinger Technique for Peritoneal Dialysis Catheter Insertion
Published on: May 23, 2025
Minimally invasive 'pull technique' for peritoneal dialysis catheter removal
Jian Wang1, Xiao-Sheng Li1, Feng-Xia Zhang1
1Department of Nephrology, The First Affiliated Hospital of Gannan Medical University, Ganzhou, China.
Abstract:
A simple, noninvasive method for removing peritoneal dialysis (PD) catheters, called the "pull technique," has become popular in recent years. Physicians still worry, however, about the range of its application and possible complications such as infection of the retained cuff and breakage. We, therefore, applied this technique in patients and enriched its administration for removing PD catheters. Altogether, 24 PD catheter removals in 24 patients were reviewed during the period from July 2018 to October 2019 in our hospital. Using the pull technique, the PD catheter's superficial cuff was dissected using an electronic knife, and the deep cuff was retained. All patients' catheters were successfully removed with no breakage. No incision or retained cuff was infected during the follow-up period (1.1-15.6 months). The appropriate peak force of pull traction was approximately 12-13 pounds, not very different from the mean maximum tensile force of 21.48 pounds for silicone tube breakage. The use of intermittent (rather than sustained) traction may reduce the breakage risk of the silicone tube. This method is a safe, practical, minimally invasive method for removing PD catheters, and it is suitable for application on special patients with peritonitis or who are on an immunosuppressant.
Insights
The "pull technique" offers a safe, minimally invasive method for removing peritoneal dialysis (PD) catheters. This approach successfully removed all catheters without breakage or infection, proving effective even for high-risk patients.
Area of Science:
- Nephrology
- Minimally Invasive Surgery
Background:
- The pull technique is a popular, noninvasive method for peritoneal dialysis (PD) catheter removal.
- Concerns exist regarding its application range and potential complications like cuff infection or catheter breakage.
Purpose of the Study:
- To evaluate the safety and efficacy of the pull technique for PD catheter removal.
- To refine the technique for improved outcomes and assess its suitability for specific patient groups.
Main Methods:
- A review of 24 PD catheter removals using the pull technique in 24 patients.
- Dissection of the superficial cuff with an electronic knife, retaining the deep cuff.
- Analysis of catheter removal success, breakage, infection, and applied traction force.
Main Results:
- All 24 PD catheters were successfully removed without breakage.
- No instances of superficial cuff or incision infection were observed during follow-up (1.1-15.6 months).
- Optimal pull traction force was identified as 12-13 pounds, below the silicone tube's mean tensile strength (21.48 pounds).
Conclusions:
- The pull technique is a safe, practical, and minimally invasive method for PD catheter removal.
- Intermittent traction may reduce the risk of catheter breakage.
- This technique is suitable for patients with peritonitis or on immunosuppressants.