Use of venous couplers in microsurgical lower extremity reconstruction: A systematic review and meta-analysis
Valentin Haug1,2, Adriana C Panayi2, Nikita Kadakia2
1Department of Hand-, Plastic and Reconstructive Surgery, Microsurgery, Burn Center, BG Trauma Center Ludwigshafen, University of Heidelberg, Ludwigshafen, Germany.
Background:
Free tissue transfer for lower limb reconstruction has become a workhorse procedure for limb-salvage. Compared with other recipient sites, the lower extremity has a higher risk of microvascular complications, in particular with venous anastomosis. The study's objective is to evaluate the evidence, safety, and efficacy of venous coupler use in microsurgical anastomosis in lower limb reconstruction to provide objective appraisal of the surgical techniques.
Methods:
A systematic review (SR) and meta-analysis (MA) were performed analyzing articles from PubMed, Cochrane, Embase, and Web of Science from January 1990, to August 2018. Abstracts and titles were screened and assessed for eligibility by independent reviewers. Following full-text review, articles were included in the SR and MA. Case reports were excluded. Cochrane Collaboration and the Quality of Reporting of Meta-analyses (QUOROM) guidelines were followed.
Results:
Out of 15 included studies that met the inclusion criteria for the SR, 9 were included in MA. Patients treated with venous couplers did not experience more surgical complications (risk ratio (RR) 0.79; 95% confidence interval (CI) 0.48-1.33; p = .38), total failure (RR 0.61; 95% CI 0.22-1.70; p = .34), venous compromise (RR 0.72; 95% CI 0.23-2.27; p = .57), arterial compromise (RR 0.85; 95% CI 0.25-2.88; p = .80), partial failure (RR 0.77; 95% CI 0.33-1.77; p = .54), or reoperation (RR 11.79; 95% CI 0.49-286.55; p = .13) in comparison with hand-sewn anastomosis.
Conclusions:
Outcomes of venous couplers in lower limb reconstruction are comparable to those of hand-sewn anastomosis. However, this study was limited by the quality of the available literature. Additional prospective studies should aim to directly compare both techniques and potential further benefits in clinical trials.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Varicose Veins II: Diagnostic Studies and Interprofessional Care
Venous Thrombosis III: Interprofessional Care
Venous Thrombosis I: Introduction
Venous Thrombosis IV: Nursing Management
Veins of Lower Limbs