Related Experiment Video
Updated: Dec 25, 2025

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Personalized application of three different concentrations of iodinated contrast media in coronary computed
Meng Zhang1, Panpan Hao1, Chenyu Jiang2
1The Key Laboratory of Cardiovascular Remodeling and Function Research, Chinese Ministry of Education, Chinese National Health Commission and Chinese Academy of Medical Sciences, The State and Shandong Province Joint Key Laboratory of Translational Cardiovascular Medicine, Department of Cardiology, Qilu Hospital of Shandong University, Jinan, China.
Abstract:
No study has evaluated the impact of different iodinated contrast media on coronary contrast enhancement, using an injection protocol according to body surface area (BSA). Thus, the present study aimed to examine the usefulness and safety of personalized application of different iodine concentrations of contrast media in coronary computed tomographic (CT) angiography with a 2nd dual-source CT scanner in eliminating differences in coronary contrast enhancement based on a BSA-adapted injection protocol of contrast media. A total of 270 enrolled participants were randomly assigned to three groups: ioversol 320, ioversol 350 and iopromide 370 (n = 90 per group). The three groups were administered contrast media at a BSA-adjusted volume and flow rate with a fixed injection time of 15 seconds, and they subsequently received a 30-mL saline flush. All patients were scanned with a prospective electrocardiogram-gated protocol in a craniocaudal direction using a second-generation 128-slice dual-source CT system. The three iodinated contrast media used in coronary CT angiography exhibited similar diagnostic quality and safety. No significant differences were found in the contrast enhancement degrees, image quality scores, radiation doses and incidences of adverse effects among the three groups. The three contrast media used in coronary CT angiography with 320, 350 and 370 mg/mL iodine, respectively, have comparable diagnostic quality and safety. However, more large-scale, multinational, multi-centre and prospective trials are warranted.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Cardiac Catheterization I: Pre-Procedure Overview
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System IV: CMRI