Related Experiment Video
Updated: Dec 25, 2025

Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
Combining Volumetric and Wall Shear Stress Analysis from CT to Assess Risk of Abdominal Aortic Aneurysm Progression
Olivier Meyrignac1, Laurence Bal1, Charline Zadro1
1From the Department of Radiology, Institut Universitaire du Cancer de Toulouse, Avenue Irène Joliot Curie, 31100 Toulouse, France (O.M.); Department of Radiology, CHU Toulouse Rangueil, Toulouse, France (O.M., C.Z., A.V., P.R.M., J.D., H.R.); INSERM, UMR1048, Institut des Maladies Métaboliques et Cardiovasculaire, Toulouse, France (O.M., C.Z., A.V., A. Sewonu, B.S.L., P.R.M., J.D., A.N.S., H.R., R.M.); Department of Vascular Surgery, Centre Aorte Timone, APHM, CHU de La Timone Adultes, Marseille, France (L.B., M.G., M.D.M., P.P.); ALARA Expertise, Strasbourg, France (A. Sewonu, R.M.); Department of Fundamental Pharmaco-Clinical Pharmacology, Université Paul Sabatier, Toulouse, France (A. Sommet); Department of Vascular Surgery, CHU Toulouse Rangueil, Toulouse, France (B.S.L.); and Department of Radiology, Centre Aorte Timone, APHM, CHU de La Timone Adultes, Marseille, France (A.J., J.M.B.).
Abstract:
Background Despite known limitations, the decision to operate on abdominal aortic aneurysm (AAA) is primarily on the basis of measurement of maximal aneurysm diameter. Purpose To identify volumetric and computational fluid dynamics parameters to predict AAAs that are likely to progress in size. Materials and Methods This study, part of a multicenter prospective registry (NCT01599533), included 126 patients with AAA. Patients were sorted into stable (≤10-mL increase in aneurysm volume) and progression (>10-mL increase in aneurysm volume) groups. Initial AAA characteristics of the derivation cohort were analyzed (maximal diameter and surface, thrombus and lumen volumes, maximal wall pressure, and wall shear stress [WSS]) to identify relevant parameters for a logistic regression model. Model and maximal diameter diagnostic performances were assessed in both cohorts and for AAAs smaller than 50 mm by using area under the receiver operating characteristic curve (AUC). Results Eighty-one patients were included (mean age, 73 years ± 7 years [standard deviation]; 78 men). The derivation and validation cohorts included, respectively, 50 and 31 participants. In the derivation cohort, there was higher mean lumen volume and lower mean WSS in the progression group compared with the stable group (60 mL ± 14 vs 46 mL ± 18 [P = .005] and 66% ± 6 vs 53% ± 9 [P = .02], respectively). Mean lumen volume and mean WSS at baseline were correlated to total volume growth (r = 0.47 [P = .002] and -0.42 [P = .006], respectively). In the derivation cohort, a regression model including lumen volume and WSS to predict aneurysm enlargement was superior to maximal diameter alone (AUC, 0.78 vs 0.52, respectively; P = .003); although no difference was found in the validation cohort (AUC, 0.79 vs 0.71, respectively; P = .51). For AAAs smaller than 50 mm, a regression model that included both baseline WSS and lumen volume performed better than maximal diameter (AUC, 0.79 vs 0.53, respectively; P = .01). Conclusion Combined analysis of lumen volume and wall shear stress was associated with enlargement of abdominal aortic aneurysms at 1 year, particularly in aneurysms smaller than 50 mm in diameter. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Mitsouras and Leach in this issue.
More Related Videos
09:32Manufacturing Abdominal Aorta Hydrogel Tissue-Mimicking Phantoms for Ultrasound Elastography Validation
Published on: September 19, 2018
06:46Quantitative Micro-CT Analysis of Aortopathy in a Mouse Model of β-aminopropionitrile-induced Aortic Aneurysm and Dissection
Published on: July 16, 2018
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Aneurysm III: Interprofessional Care
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System V: CT