The application of comprehensive two-dimensional gas chromatography to the analysis of wildfire debris for ignitable
Lisa N Kates1, Philip I Richards1, Court D Sandau2
1Chemistry Matters, Inc., Suite 405, 104 - 1240 Kensington Road NW, Calgary, Alberta, T2N 3P7, Canada.
Abstract:
Arsonous wildfires are complex investigations due to the high abundance of natural background compounds and subsequent pyrolysis by-products formed during combustion. These interfering compounds can be present in large concentrations and overwhelm the marker compounds used to identify ignitable liquid residue (ILR). Complex matrix effects often interfere with the identification of ILR, providing ambiguous results. The use of comprehensive two-dimensional gas chromatography with time of flight mass spectrometry (GC×GC-TOFMS) separates natural compounds from interfering with ILR compounds of interest. When compared to standard gas chromatography-mass spectrometry (GC-MS) analysis, GC×GC was able to reduce the number of tentative results by 20%. Certain compounds were determined to be unusable for the identification of ILR in wildfire debris samples, in particular the Three Musketeer Group (ethylbenzene, m,p-xylene, and o-xylene), which are ubiquitous in all samples, as well as long chain n-alkylbenzenes, which are formed in the pyrolysis of organic matter. Conversely, the presence of C1- and C2-alkylnaphthalenes were excellent indicators of the presence of gasoline-type ILR. A sizeable number of background samples were collected that helped to provide additional lines of evidence when classifying samples for ILR. Given the complicated matrices encountered in arsonous wildfires, it is evident that GC×GC provides better capabilities at identifying ILR than the standard GC-MS analytical technique.
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...