Complete ejection of a ring sequestrum 8 years after external fixation of the tibia
Isabella Regina Timmer1, Benjamin Lucas Emmink2,3, Loek Petrus Hendrikus Leenen1
1Department of Trauma Surgery, University Medical Center Utrecht, Utrecht, The Netherlands.
BMJ Case Reports
|April 2, 2020
Summary
A man with a persistent pin tract infection spontaneously ejected a bony sequestrum from his tibial wound. This complication stemmed from an external fixator placed without predrilling eight years prior.
Area of Science:
- Orthopedic surgery
- Infectious disease
Background:
- A 23-year-old male presented with a persistent pin tract infection.
- The patient had a history of an open crural fracture treated 8 years prior.
Observation:
- The patient presented with a spontaneously ejected bony ring sequestrum from his tibial wound.
- The external fixator used for the initial fracture treatment was placed without predrilling.
Findings:
- The ejected bony sequestrum suggests a complication related to the prior external fixator placement.
- Persistent pin tract infection can lead to the formation and expulsion of bone sequestra.
Implications:
- This case highlights the potential long-term complications of external fixator application without proper predrilling.
- Early recognition and management of pin tract infections are crucial to prevent further complications like sequestrum formation.