The association between arterial pulse waveform analysis device and in-hospital mortality in high-risk non-cardiac
Chikashi Takeda1,2, Masato Takeuchi1, Toshiyuki Mizota2
1Department of Pharmacoepidemiology, Graduate School of Medicine and Public Health, Kyoto University, Kyoto, Japan.
Background:
Perioperative goal-directed fluid therapy is used for haemodynamic optimization in high-risk surgeries. Cardiac output monitoring can be performed by a specialized pressure transducer for arterial pulse waveform analysis (S-APWA). No study has assessed whether real-world use of S-APWA is associated with post-operative outcomes; therefore, using a Japanese administrative claims database, we retrospectively investigated whether S-APWA use is associated with in-hospital mortality among patients undergoing high-risk surgery under general anaesthesia.
Methods:
Adult patients who underwent high-risk surgery under general anaesthesia and arterial catheterization between 2014 and 2016 were divided into S-APWA and conventional arterial pressure transducer groups, then compared regarding baseline factors and outcomes. Logistic regression analysis was performed to compare in-hospital mortality. Subgroup analyses evaluated S-APWA efficacy and outcomes based on the type of surgery and patients' comorbidity.
Results:
S-APWA was used in 6859 of 23 655 (29.0%) patients; the crude in-hospital mortality rate was 3.5%. Adjusted analysis showed no significant association between S-APWA use and in-hospital mortality rate (adjusted odds ratio [aOR] = 0.91; 95% confidence interval [CI]: 0.76-1.07; P = .25). S-APWA use was associated with significantly lower in-hospital mortality in patients undergoing vascular surgery (aOR = 0.67; 95% CI: 0.49-0.94), and significantly higher in-hospital mortality in patients undergoing lower limb amputation (aOR = 2.63; 95% CI: 1.32-5.22). S-APWA use and in-hospital mortality were not significantly associated with other subgroups.
Conclusion:
S-APWA use was not associated with in-hospital mortality in the entire study population. However, S-APWA was associated with decreased in-hospital mortality among vascular surgery and increased in-hospital mortality among lower limb amputation.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pulse
The pulse serves as a clinical...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Artery Disease V: Postoperative Nursing Management