Related Experiment Video
Updated: Dec 25, 2025

The Intra-Aortic Balloon Pump
Published on: February 5, 2021
Percutaneous Left Axillary Artery Placement of Intra-Aortic Balloon Pump in Advanced Heart Failure Patients
Arvind Bhimaraj1, Tanushree Agrawal2, Antonio Duran2
1Houston Methodist DeBakey Heart and Vascular Center, Houston Methodist Hospital, Houston, Texas.
Objectives:
This study presents the largest clinical experience of percutaneously placed axillary intra-aortic balloon pump (IABP) in patients with advanced heart failure.
Background:
Transfemoral placement of IABP limits mobility and recuperation in patients who need prolonged support. We had previously reported a novel percutaneous method of IABP placement in the axillary artery and now present our expanded experience with this technique.
Methods:
We performed a retrospective chart review of patients with advanced heart failure with percutaneous axillary IABP placement from November 2007 to June 2018 at Houston Methodist Hospital. We defined successful cardiac replacement therapy as heart transplant or left ventricular assist device implantation. We compared patients who had successful cardiac replacement with those who died and those who needed unplanned escalation of mechanical circulatory support.
Results:
Of the 195 patients identified, 133 (68%) underwent successful cardiac replacement (120 transplants and 13 left ventricular assist device) as planned. End-organ function improved on IABP support in patients bridged to next therapy. There were 16 patients that died while on IABP support and 18 needed escalation of support. Higher right atrial/wedge ratio, higher right atrial pressure, smaller left ventricular end diastolic dimension, and ischemic cardiomyopathy were associated with death on the IABP in multivariate analysis. Post-transplant and post left ventricular assist device survival for those bridged successfully was 87% and 62%, respectively. Although bedside repositioning was frequent, 37% needed replacement for malfunction. Vascular complications occurred in a minority.
Conclusions:
Percutaneous axillary approach for IABP placement is a feasible strategy for prolonged mechanical circulatory support in patients with advanced heart failure.
More Related Videos
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
Related Concept Videos
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization II: Right Heart Catheterization