Ultrasound-based estimation of remaining cardiac function in LVAD-supported ex vivo hearts
Louis S Fixsen1, Niels J Petterson1, Patrick Houthuizen2
1Cardiovascular Biomechanics group, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
Abstract:
Left ventricular assist devices (LVAD) provide cardiac support to patients with advanced heart failure. Methods that can directly measure remaining LV function following device implantation do not currently exist. Previous studies have shown that a combination of loading (LV pressure) and deformation (strain) measurements enables quantitation of myocardial work. We investigated the use of ultrasound (US) strain imaging and pressure-strain loop analysis in LVAD-supported hearts under different hemodynamic and pump unloading conditions, with the aim of determining LV function with and without LVAD support. Ex vivo porcine hearts (n = 4) were implanted with LVADs and attached to a mock circulatory loop. Measurements were performed at hemodynamically defined "heart conditions" as the hearts deteriorated from baseline. Hemodynamic (including LV pressure) and radio-frequency US data were acquired during a pump-ramp protocol at speeds from 0 (with no pump outflow) to 10 000 revolutions per minute (rpm). Regional circumferential (εcirc ) and radial (εrad ) strains were estimated over each heart cycle. Regional ventricular dyssynchrony was quantitated through time-to-peak strain. Mean change in LV pulse pressure and εcirc between 0 and 10 krpm were -21.8 mm Hg and -7.24% in the first condition; in the final condition -46.8 mm Hg and -19.2%, respectively. εrad was not indicative of changes in pump speed or heart condition. Pressure-strain loops showed a degradation in the LV function and an increased influence of LV unloading: loop area reduced by 90% between 0 krpm in the first heart condition and 10 krpm in the last condition. High pump speeds and degraded condition led to increased dyssynchrony between the septal and lateral LV walls. Functional measurement of the LV while undergoing LVAD support is possible by using US strain imaging and pressure-strain loops. This can provide important information about remaining pump function. Use of novel LV pressure estimation or measurement techniques would be required for any future use in LVAD patients.
More Related Videos
08:19Transthoracic Echocardiography to Assess Post-Resuscitation Left Ventricular Dysfunction After Acute Myocardial Infarction and Cardiac Arrest in Pigs
Published on: July 12, 2022
08:49Author Spotlight: Enhancing Graft Viability Assessment Through Quantitative Metrics and Innovative Reservoir Systems
Published on: August 2, 2024