Related Experiment Video
Updated: Dec 25, 2025

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Computerised occlusal analysis of mini-dental implant-retained mandibular overdentures: A 1-year prospective clinical
Phongkamon Kabbua1, Weerapan Aunmeungtong1, Pathawee Khongkhunthian1
1Center of Excellence for Dental Implantology, Faculty of Dentistry, Chiang Mai University, Chiang Mai, Thailand.
Abstract:
Occlusal analysis is a substantial tool for the functional improvement evaluation after using implant-retained overdenture comparing to complete denture without dental implant retaining. To evaluate occlusal pattern, chewing force distribution in mini-dental implant-retained mandibular overdentures by computerised occlusal analysis system and to compare patient satisfaction after 1-year function. Thirty-one patients wearing complete dentures were included in the study. Prior to mini-dental implant-retained treatment, all patients were assessed for occlusion and force distribution using computerised occlusal analysis system (T-Scan® ), and then, all patients received two mini-dental implant-retained mandibular overdentures. Mini-dental implants were immediately loaded using low vertical profile attachments (Equator® ). T-Scan® was used to evaluate chewing force and force distribution at 1 day, 3 months, 6 months and 12 months. The patient satisfactions before implant placement and after 1 year were evaluated using questionnaires which included satisfaction of denture quality, psychosocial behaviour and chewing efficiency modified from the validated questionnaires. Clinical evaluation of two mini-dental implant-retained mandibular overdentures showed 100% success rate after 1 year. T-Scan® demonstrated that maximum occlusal contact force increased continuously. The force distribution; the tooth contact number increased over the period. At 1-year follow-up, overall patient satisfaction was significantly greater than before receiving mini-dental implant treatment (P < .001). Using computerised occlusal analysis, mini-dental implants improve complete denture function significantly in terms of maximum occlusal contact force, tooth contact number without the impairment of force distribution. The oral function of the patients has been enhanced.
More Related Videos
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
07:32Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024