Related Experiment Video
Updated: Dec 25, 2025

Two-way Valorization of Blast Furnace Slag: Synthesis of Precipitated Calcium Carbonate and Zeolitic Heavy Metal Adsorbent
Published on: February 21, 2017
Severe Sulfuric Acid Attack on Self-Compacting Concrete with Granulometrically Optimized Blast-Furnace
Sara Irico1, Laurence De Meyst2, Dirk Qvaeschning1
1Wilhelm Dyckerhoff Institut for Building Material Technology, Dyckerhoff GmbH, Dyckerhoffstraße 7, 65203 Wiesbaden, Germany.
Abstract:
The corrosion by severe sulfuric acid attack at pH 2 of two self-compacting concrete (SCC) types that are based on ordinary Portland cement (OPC) and granulometrically optimized blast-furnace slag cement was evaluated by three complementary tests that were performed in different research institutes. The use of SCC is a smart and promising solution to improve the performance of concrete in an aggressive environment, especially regarding ready-mixed concrete applications, since good compaction is less dependent on workmanship. The relevance and practical advantages of the different test protocols and the influence of the experimental parameters are discussed. It appears that the frequency of renewing the acid solution during the exposure period is the main parameter that influences the mass loss and the rate of degradation, while the sample geometry and the ratio between the volume of solution and concrete surface area had no clear influence. Nevertheless, there was reasonable agreement between the methods regarding the magnitude of the concrete degradation (resulting in a mass loss of about 2.5 kg/m² in six months time). The use of granulometrically optimized slag cement provided a moderate increase of the concrete resistance against acid attack, and this practice might be recommended in order to increase the durability of structures exposed to sulfuric acid media. The fact that the difference in comparison with SCC-OPC was rather limited shows that the influence of the cement type becomes less relevant in the case of concrete with low w/c ratio and optimized concrete technology.
More Related Videos
Related Concept Videos
Sulfate Attack on Concrete
Sulfates from sources like soil, groundwater, or industrial effluents...
Acid Attack on Concrete
The rate at which hydrogen...
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Alkali Aggregate Reaction in Concrete
Deleterious Substances in Aggregate
Another type of impurity is clay and fine material that...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...

