Related Experiment Video
Updated: Jul 6, 2026

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
BowelScope: Accuracy of Detection Using Endocuff Optimisation of Mucosal Abnormalities (the B-ADENOMA Study): a
Colin J Rees1, Andrew Brand2, Wee Sing Ngu3
1Northern Institute for Cancer Research, Newcastle University, Newcastle upon Tyne, UK Colin.Rees@newcastle.ac.uk.
Objectives:
Adenoma detection rate (ADR) is an important quality marker at lower GI endoscopy. Higher ADRs are associated with lower postcolonoscopy colorectal cancer rates. The English flexible sigmoidoscopy (FS) screening programme (BowelScope), offers a one-off FS to individuals aged 55 years. However, variation in ADR exists. Large studies have demonstrated improved ADR using Endocuff Vision (EV) within colonoscopy screening, but there are no studies within FS. We sought to test the effect of EV on ADR in a national FS screening population.
Design:
BowelScope: Accuracy of Detection Using ENdocuff Optimisation of Mucosal Abnormalities was a multicentre, randomised controlled trial involving 16 English BowelScope screening centres. Individuals were randomised to Endocuff Vision-assisted BowelScope (EAB) or Standard BowelScope (SB). ADR, polyp detection rate (PDR), mean adenomas per procedure (MAP), polyp characteristics and location, participant experience, procedural time and adverse events were measured. Comparison of ADR within the trial with national BowelScope ADR was also undertaken.
Results:
3222 participants were randomised (53% male) to receive EAB (n=1610) or SB (n=1612). Baseline demographics were comparable between arms. ADR in the EAB arm was 13.3% and that in the SB arm was 12.2% (p=0.353). No statistically significant differences were found in PDR, MAP, polyp characteristics or location, participant experience, complications or procedural characteristics. ADR in the SB control arm was 3.1% higher than the national ADR.
Conclusion:
EV did not improve BowelScope ADR when compared with SB. ADR in both arms was higher than the national ADR. Where detection rates are already high, EV is unable to improve detection further.
Trial Registration Numbers:
NCT03072472, ISRCTN30005319 and CPMS ID 33224.
More Related Videos
09:42Murine Endoscopy for In Vivo Multimodal Imaging of Carcinogenesis and Assessment of Intestinal Wound Healing and Inflammation
Published on: August 26, 2014
03:43Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Urologic Endoscopic Procedure: Cystoscopic Examination