Related Experiment Video
Updated: Dec 24, 2025

Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Precise pulmonary scanning and reducing medical radiation exposure by developing a clinically applicable intelligent
Yang Wang1, Xiaofan Lu2, Yingwei Zhang3
1Department of Radiology, The Affiliated Nanjing Drum Tower Hospital of Nanjing University Medical School, Nanjing 210008, PR China.
Background:
Interstitial lung disease requires frequent re-examination, which directly causes excessive cumulative radiation exposure. To date, AI has not been applied to CT for enhancing clinical care; thus, we hypothesize AI may empower CT with intelligence to realize automatic and accurate pulmonary scanning, thus dramatically decrease medical radiation exposure without compromising patient care.
Methods:
Facial boundary detection was realized by recognizing adjacent jaw position through training and testing a region proposal network (RPN) on 76,882 human faces using a preinstalled 2-dimensional camera; the lung-fields was then segmented by V-Net on another training set with 314 subjects and calculated the moving distance of the scanning couch based on a pre-generated calibration table. A multi-cohort study, including 1,186 patients was used for validation and radiation dose quantification under three clinical scenarios.
Findings:
A U-HAPPY (United imaging Human Automatic Planbox for PulmonarY) scanning CT was designed. Error distance of RPN was 4·46±0·02 pixels with a success rate of 98·7% in training set and 2·23±0·10 pixels with 100% success rate in testing set. Average Dice's coefficient was 0·99 in training set and 0·96 in testing set. A calibration table with 1,344,000 matches was generated to support the linkage between camera and scanner. This real-time automation makes an accurate plan-box to cover exact location and area needed to scan, thus reducing amounts of radiation exposures significantly (all, P<0·001).
Interpretation:
U-HAPPY CT designed for pulmonary imaging acquisition standardization is promising for reducing patient risk and optimizing public health expenditures.
Funding:
The National Natural Science Foundation of China.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET